To detach male type terminals (pump side) it is
necessary to press the coaxial rings towards the
pump, and extract the terminals.
CAUTION
DO NOT FORCE THE TERMINAL IF THIS DOES NOT COME
LOOSE; EVENTUALLY, TRY TWISTING IT. THE TERMINAL
IS DESIGNED SO THAT AN INCREASE IN TENSION IN-
CREASES THE LOCKING FORCE.
The system pressure check must be carried out,
for practical reasons, by connecting on the pump
side.
Connect the manometer to the outlet duct (RHS)
and the extension tube to the inlet duct (LHS).
CAUTION
BEFORE REASSEMBLING CHECK THE TOOL DUCTS ARE
CLEAN.
Pressure regulator check
1
- Connect the diagnostic tester.
Specific tooling
020680Y
Diagnosis Tool
Select the menu on the "ACTIVE DIAGNOSIS"
function.
Select the "PUMP DIAGNOSIS" function.
YES go to 2
2
- Enable the function with continuous power sup-
ply on and engine off.
The control unit starts the pump for 30 seconds
YES go to 3
3
- Let the system bleed for a few seconds.
Make sure that there are no external leaks.
Beverly 500 i.e.
Injection
INJEC - 199
Summary of Contents for Beverly 500 i.e.
Page 1: ...WORKSHOP MANUAL 633387 Beverly 500 i e...
Page 5: ...INDEX OF TOPICS CHARACTERISTICS CHAR...
Page 17: ...INDEX OF TOPICS MAINTENANCE MAIN...
Page 32: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS...
Page 51: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE...
Page 54: ...INDEX OF TOPICS ENGINE ENG...
Page 162: ...Countershaft fixing nut 25 29 Engine Beverly 500 i e ENG 162...
Page 163: ...INDEX OF TOPICS INJECTION INJEC...
Page 260: ...INDEX OF TOPICS SUSPENSIONS SUSP...
Page 284: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS...
Page 301: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS...
Page 310: ...INDEX OF TOPICS CHASSIS CHAS...
Page 329: ...INDEX OF TOPICS PRE DELIVERY PRE DE...
Page 333: ...INDEX OF TOPICS TIME TIME...