![Phytec phyCORE-167CR Hardware Manual Download Page 88](http://html1.mh-extra.com/html/phytec/phycore-167cr/phycore-167cr_hardware-manual_1554145088.webp)
phyCORE-167CR/167CS
78
PHYTEC Meßtechnik GmbH 2002 L-527e_8
2.
The CAN transceiver populating the phyCORE-167CS is disabled;
CAN signals generated by the CAN transceiver (U3) on the
Development Board extending to connector P2B without galvanic
seperation:
Jumper
Setting
Description
JP33
2 + 4
Pin 2 of the DB-9 plug P2B is connected to CAN-L1
from on-board transceiver on the phyCORE module
JP34
2 + 3
Pin 7 of the DB-9 plug P2B is connected to CAN-H1
from on-board transceiver on the phyCORE module
JP14
2 + 3
Input at opto-coupler U6 on the Development Board
connected to CAN2_Tx (P4.7
1 + 2
Input at opto-coupler U6 on the Development Board
connected to CAN2_Tx (P8.3
JP15
2 + 3
Output at opto-coupler U7 on the Development Board
connected to CAN2_Rx (P4.4
1 + 2
Output at opto-coupler U7 on the Development Board
connected to CAN2_Rx (P8.2
JP13
open
CAN transceiver and opto-coupler on the Development
Board disconnected from supply voltage
JP18
open
No GND potential at CAN transceiver and opto-coupler
on the phyCORE Development Board HD200
JP29
open
No power supply via CAN bus
Table 42:
Jumper Configuration for CAN Plug P2B using the CAN Transceiver
on the phyCORE-167CS
Pin 3:
GND (Development Board Ground)
Pin 7:
CAN-H0 (not galvanically separated)
Pin 2:
CAN-L0 (not galvanically separated)
Pin 6:
GND (Development Board Ground
Figure 21:
Pin Assignment of the DB-9 Plug P2B (CAN Transceiver on
Development Board, only with C167CS)
1:
Port P4.7 is the default port for CAN2_Tx (standard).
2:
Port P8.3 is the alternative port for CAN2_Tx (see C167CS User‘s Manual/Data Sheet).
3:
Port P4.4 is the default port for CAN2_Rx (standard).
4:
Port P8.2 is the alternative port for CAN2_Rx (see C167CS User‘s Manual/Data Sheet).
1
2
3
4
7
6
5
8
9
Summary of Contents for phyCORE-167CR
Page 10: ...phyCORE 167CR 167CS PHYTEC Me technik GmbH 2002 L 527e_8...
Page 24: ...phyCORE 167CR 167CS 14 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 40: ...phyCORE 167CR 167CS 30 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 50: ...phyCORE 167CR 167CS 40 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 102: ...phyCORE 167CR 167CS 92 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 112: ...phyCORE 167CR 167CS 102 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 114: ...Published by PHYTEC Me technik GmbH 2002 Ordering No L 527e_8 Printed in Germany...