![Phytec phyCORE-167CR Hardware Manual Download Page 22](http://html1.mh-extra.com/html/phytec/phycore-167cr/phycore-167cr_hardware-manual_1554145022.webp)
phyCORE-167CR/167CS
12
PHYTEC Meßtechnik GmbH 2002 L-527e_8
Pin Number
Signal
I/O
Description
Pin Row X1C
1C, 2C
VCC
-
Voltage input +5 =
3C, 7C, 12C, 17C,
22C, 27C, 32C,
37C
GND
-
Ground 0 V
4C, 5C
NC
-
Not connected
These contacts should remain unconnected on the
target hardware side.
6C
VBAT
I
Battery input for back-up of RTC and buffering of
RAM
8C
/PFO
O
MAX 690/ Power-Fail output
9C
BOOT
I
Input for startup of FlashTools
10C
/RESET
I
/RESET input of the phyCORE-167CR/167CS
11C
/RESOUT
O
/RESOUT signal of µC
13C, 14C,
15C, 16C,
19C, 20C
P2.2, P2.4,
P2.5, P2.7,
P2.11, P2.12
I/O
Port 2 of the microcontroller (see corresponding
Data Sheet)
18C
CAN-H1
1
I/O
Differential CANH line of second CAN transceiver
21C
RxD1_RS232
I
Input of the second interface series of the
phyCORE-167CR/167CS, RS-232 level
23C
TxD1_RS232
O
Output of the second interface series of the
phyCORE-167CR/167CS, RS-232 level
24C
/RTS1_RS232
O
/RTS signal of the UART U7, RS-232 level
25C
/CTS1_RS232
I
/CTS signal of the UART U7, RS-232 level
26C
/DSR1_RS232 I
/DSR signal of the UART U7, RS-232 level
28C
/DTR1_RS232 O
/DTR signal of the UART U7, RS-232 level
29C
/RI1_TTL
I
/RI signal of the UART U7, TTL level
30C
/CD1_TTL
I
/CD signal of the UART U7, TTL level
31C
SCL
O
CLK line I
2
C bus
33C
IRQ_UART
O
Interrupt output of the UART U7
34C
/CS_UART
I
Chip Select signal of the UART U7
35C, 36C
P8.4, P8.6
I/O
CAPCOM2:CC20 Capture Input/Compare Output
CAPCOM2:CC22 Capture Input/Compare Output
38C, 39C, 40C
NC
-
Not connected
These contacts should remain unconnected on the
target hardware side.
41C, 43C,
44C, 45C,
46C,48C,
49C,50C
P5.14 P5.11,
P5.9, P5.8,
P5.6, P5.3,
P5.1, P5.0
I/O
Port 5 of the microcontroller (see corresponding
Data Sheet)
42C, 47C
VAGND
-
Analog Ground of the microcontroller
Summary of Contents for phyCORE-167CR
Page 10: ...phyCORE 167CR 167CS PHYTEC Me technik GmbH 2002 L 527e_8...
Page 24: ...phyCORE 167CR 167CS 14 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 40: ...phyCORE 167CR 167CS 30 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 50: ...phyCORE 167CR 167CS 40 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 102: ...phyCORE 167CR 167CS 92 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 112: ...phyCORE 167CR 167CS 102 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 114: ...Published by PHYTEC Me technik GmbH 2002 Ordering No L 527e_8 Printed in Germany...