phyCORE-167CR/167CS
18
PHYTEC Meßtechnik GmbH 2002 L-527e_8
Default Setting
Alternative Setting
J18
(2+3)
CAN1 transmit line
(CANTx) of the CAN
transceiver at U12
connected to Port 4.7
(A23) of the controller
(see
µC
Data Sheet)
(1+2)
CAN1 transmit line
(CANTx) of the CAN
transceiver at U12
connected to P8.3 of the
microcontroller (see
controller Data Sheet)
J19
1
(2+3)
CAN1 receive line
(CANRx) of the CAN
transceiver at U12 con-
nected to Port P4.4 (A20)
of the microcontroller
(see
µC
Data Sheet)
(1+2)
CAN1 receive line
(CANRx) of the CAN
transceiver at U12 con-
nected to P8.2 of the
microcontroller (see
controller Data Sheet)
J20
(open)
Remote Download not
connected
(1+2)
Remote Download
Source at P3.1
(3+5)
Remote Download
Source CAN1Rx
(3+4)
Remote Download
Source CAN2Rx
(2+6)
Remote Download
Source P3.11
J21
(closed)
P3.11 used as RXD0 and
conected to RS-232
transceiver U6
(open)
P3.11 of the controller is
freely available as
standard I/O at pin header
row X1D16
J22
(closed)
2
P3.10 used as TXD0 and
conected to RS-232
transceiver U6
(open)
P3.10 of the controller is
freely available as
standard I/O at pin header
row X1D17
J23
(closed)
Pin 17 of the controller is
connected to VCC
(open)
Pin 17 of the controller is
connected to GND via a
bypass capacitor
J24
(closed)
Pin 56 of the controller is
connected to VCC
(open)
Pin 56 of the controller is
connected to GND via a
bypass capacitor
Table 2:
Jumper Settings
1
:
The second CAN interface is only available with Infineon‘s C167CS (refer to the controller
Data Sheet).
2
:
Note: These jumpers must remain closed on the phyCORE-167CR/167CS. If they are open,
no serial communication is possible, hence PHYTEC FlashTools or the BOOT monitor will
not function properly.
Summary of Contents for phyCORE-167CR
Page 10: ...phyCORE 167CR 167CS PHYTEC Me technik GmbH 2002 L 527e_8...
Page 24: ...phyCORE 167CR 167CS 14 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 40: ...phyCORE 167CR 167CS 30 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 50: ...phyCORE 167CR 167CS 40 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 102: ...phyCORE 167CR 167CS 92 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 112: ...phyCORE 167CR 167CS 102 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 114: ...Published by PHYTEC Me technik GmbH 2002 Ordering No L 527e_8 Printed in Germany...