phyCORE-167CR/167CS
68
PHYTEC Meßtechnik GmbH 2002 L-527e_8
Caution:
When using the DB-9 socket P1B with the configuration of the
phyCORE-167CR/167CS as described above the following jumper
settings are not functional and could damage the module:
Jumper
Setting
Description
JP1
closed
No TxD1_RS232 signal available from the
phyCORE-167CR/167CS (P1B pin 2)
JP2
closed
No RI1_TTL signal available from the
phyCORE-167CR/167CS (P1B pin 9)
JP3
closed
No CTS1_RS232 signal available from the
phyCORE-167CR/167CS (P1B pin 7)
JP4
closed
No DSR1_RS232 signal available from the
phyCORE-167CR/167CS (P1B pin 4)
JP5
closed
No DTR1_RS232 signal available from the
phyCORE-167CR/167CS (P1B pin 6)
JP6
closed
No RTS1_RS232 signal available from the
phyCORE-167CR/167CS (P1B pin 8)
JP7
closed
No CD1_RS232 signal available from the
phyCORE-167CR/167CS (P1B pin 1)
JP8
closed
No RxD1_RS232 signal available from the
phyCORE-167CR/167CS (P1B pin 3)
Table 32:
Improper Jumper Settings for DB-9 Socket P1B (no second RS-232)
If an RS-232 cable is connected to P1B by mistake, the voltage level
on the RS-232 lines could destroy the phyCORE-167CR/167CS.
Summary of Contents for phyCORE-167CR
Page 10: ...phyCORE 167CR 167CS PHYTEC Me technik GmbH 2002 L 527e_8...
Page 24: ...phyCORE 167CR 167CS 14 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 40: ...phyCORE 167CR 167CS 30 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 50: ...phyCORE 167CR 167CS 40 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 102: ...phyCORE 167CR 167CS 92 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 112: ...phyCORE 167CR 167CS 102 PHYTEC Me technik GmbH 2002 L 527e_8...
Page 114: ...Published by PHYTEC Me technik GmbH 2002 Ordering No L 527e_8 Printed in Germany...