Chapter 4 Functions
44
4.7.
IRIG Time Code (External Time Synchronization)
The system supports IRIG-B input and can add an IRIG code to each recorded frame. The sample
timing for the IRIG code is once each frame.
The recorded IRIG code is displayed on the “Photron FASTCAM VIEWER” software.
IRIG Code Input Specification
Connector
BNC
Code Format
IRIG-B (122) Analog
Amplitude
1.0Vp-p min,8.0Vp-p max
Mark to space ratio
3:1 to 6:1
Typical modulated carrier signal ratio
10:1
IRIG Time Code is used when synchronizing a camera with external equipment in time.
It is a convenient function when apparatus is physically separated.
When the IRIG code is being input, the IRIG code is displayed in white, and is displayed to the left.
The IRIG offset time is also displayed below it. When the IRIG code is not being input, the IRIG
code is displayed in grey. At that time, the counter is the camera’s internal counter and it continues
to count.
Limitation of use of IRIG code
With the Image Trigger function, IRIG code cannot be used when the specified number of frames is
32 or fewer in RANDOM CENTER or RANDOM MANUAL trigger mode.
Summary of Contents for FASTCAM Multi
Page 1: ...F FA AS ST TC CA AM M M Mu ul lt ti i ...
Page 11: ......
Page 14: ...7 1 Contact Information 66 ...
Page 15: ...1 Chapter 1 Overview 1 1 Product Overview and Features ...
Page 40: ...Chapter 3 System Connections 26 ...
Page 66: ...Chapter 4 Functions 52 ...
Page 75: ...61 FASTCAM Multi Hardware Manual 5 2 5 Clearance for Camera Cable Connection mm Minimum 275 ...
Page 76: ...Chapter 5 Product Specification 62 ...
Page 77: ...63 FASTCAM Multi Hardware Manual Chapter 6 Warranty 6 1 About the Warranty ...
Page 79: ...65 FASTCAM Multi Hardware Manual Chapter 7 Contacting Photron 7 1 Contact Information ...