12.5 Grey Level Transformation (LUT)
12.5.2
Gamma
The ’Gamma’ mode performs an exponential amplification, configurable in the range from 0.4
to 4.0. Gamma > 1.0 results in an attenuation of the image (see Fig. 12.4), gamma < 1.0 results
in an amplification (see Fig. 12.5). Gamma correction is often used for tone mapping and
better display of results on monitor screens.
0
200
400
600
800
1000
1200
0
50
100
150
200
250
300
Grey level transformation − Gamma: y = (255 / 1023
γ
)
⋅
x
γ
(
γ
≥
1)
x: grey level input value (10 bit) [DN]
y: grey level output value (8 bit) [DN]
γ
= 1.0
γ
= 1.2
γ
= 1.5
γ
= 1.8
γ
= 2.5
γ
= 4.0
Figure 12.4: Applying gamma correction to an image (gamma > 1)
0
200
400
600
800
1000
1200
0
50
100
150
200
250
300
Grey level transformation − Gamma: y = (255 / 1023
γ
)
⋅
x
γ
(
γ
≤
1)
x: grey level input value (10 bit) [DN]
y: grey level output value (8 bit) [DN]
γ
= 1.0
γ
= 0.9
γ
= 0.8
γ
= 0.6
γ
= 0.4
Figure 12.5: Applying gamma correction to an image (gamma < 1)
MAN085 04/2021 V1.3
79 of 151
Summary of Contents for Luxima DR4-D1280-L01-FB
Page 8: ...CONTENTS 8 of 151 MAN085 04 2021 V1 3...
Page 12: ...1 Preface 12 of 151 MAN085 04 2021 V1 3...
Page 42: ...4 Image Acquisition 42 of 151 MAN085 04 2021 V1 3...
Page 52: ...5 Counter Timer 52 of 151 MAN085 04 2021 V1 3...
Page 84: ...12 Pixel Data Processing 84 of 151 MAN085 04 2021 V1 3...
Page 94: ...12 Pixel Data Processing 94 of 151 MAN085 04 2021 V1 3...
Page 98: ...13 Precautions 98 of 151 MAN085 04 2021 V1 3...
Page 128: ...16 Troubleshooting 128 of 151 MAN085 04 2021 V1 3...
Page 134: ...19 Support and Repair 134 of 151 MAN085 04 2021 V1 3...
Page 136: ...20 References 136 of 151 MAN085 04 2021 V1 3...
Page 140: ...A Pinouts 140 of 151 MAN085 04 2021 V1 3...