C Use Cases
1.
Set the
LineSelector
to
LineOut0
.
2.
Set the
LineSource
of this output to the corresponding timer acitve signal:
Timer0Active
,
Timer1Active
,
Timer2Active
or
Timer3Active
.
3.
Set the polarity of this output accordingly with the parameter
LineInverter
.
C.3
Counter
There are four general purpose counters available, which can be used to count any events in
the camera. The following sections show some use cases, how the counters can be used. There
are some examples of simple counter configurations as well as some more sophisticated
settings.
C.3.1
Counter Reset
A counter needs to be reset in order to be activated after configuration. This can be done by
the software reset command
CounterReset
or by an external reset source, which can be selected
by the parameter
CounterResetSource
of the corresponding counter. Furthermore for each
counter there is an automatically counter reset at acquisition start feature available:
CounterAcquisitionStartReset
. If it is set to
True
, the corresponding counter is reset when an
acquisition start command is applied. Depending on the application, it might be necessary, that
the current counter value must not be reset at acquisition start. In this case the parameter
CounterAcquisitionStartReset
must be set to
False
for the corresponding counter and the user
must execute the parameter
CounterReset
manually for a first counter start.
C.3.2
Image Counter
Any of the four available counters can be used as an image counter. The following
configuration procedure must be applied:
1.
Select one of the four available counters by setting of the
CounterSelector
to
Counter0
,
Counter1
,
Counter2
or
Counter3
.
2.
Select the corresponding counter event source by the parameter
CounterEventSource
. Any
signal source, which is generated with every frame, can be select. For instances
FrameStart
or
ExposureStart
can be selected.
3.
Parameter
TimerTriggerActivation
can be ignored. This configuration is only necessary,
when
Line0
input is selected as a trigger source.
4.
All other counter parameter must be left in default state (Both the
CounterResetSource
and
CounterTriggerSource
must be set to
Off
)
5.
The counter needs to be reset (see C.3.1).
C.3.3
Real Time Counter
Any of the four available counters can be used as a real time counter. The following
configuration procedure must be applied:
1.
Select one of the four available counters by setting of the
CounterSelector
to
Counter0
,
Counter1
,
Counter2
or
Counter3
.
2.
Set the parameter
CounterEventSource
to
TimeStampTick
.
3.
Parameter
TimerTriggerActivation
can be ignored. This configuration is only necessary,
when
Line0
input is selected as a trigger source.
146 of 151
MAN085 04/2021 V1.3
Summary of Contents for Luxima DR4-D1280-L01-FB
Page 8: ...CONTENTS 8 of 151 MAN085 04 2021 V1 3...
Page 12: ...1 Preface 12 of 151 MAN085 04 2021 V1 3...
Page 42: ...4 Image Acquisition 42 of 151 MAN085 04 2021 V1 3...
Page 52: ...5 Counter Timer 52 of 151 MAN085 04 2021 V1 3...
Page 84: ...12 Pixel Data Processing 84 of 151 MAN085 04 2021 V1 3...
Page 94: ...12 Pixel Data Processing 94 of 151 MAN085 04 2021 V1 3...
Page 98: ...13 Precautions 98 of 151 MAN085 04 2021 V1 3...
Page 128: ...16 Troubleshooting 128 of 151 MAN085 04 2021 V1 3...
Page 134: ...19 Support and Repair 134 of 151 MAN085 04 2021 V1 3...
Page 136: ...20 References 136 of 151 MAN085 04 2021 V1 3...
Page 140: ...A Pinouts 140 of 151 MAN085 04 2021 V1 3...