14 Hardware Interface
Isolator
LineIn0
LineIn1
LineIn2
LineIn3
CAMERA_PWR
CAMERA_GND
ISO_GND
TTL120
120
10nF
17-pin M12
I/O Connector
Cam
era
Fi
rmw
are
Camera
TTL or SE-HTL
&
YOUR_POWER
YOUR_GND
YOUR_GND
R0
C0
R1
C1
R2
C2
YOUR_GND
3
4
5
6
7
8
9
2
1
12
11
17
ISO_IN0
ISO_IN1
ISO_IN2
ISO_IN3
YOUR_POWER
4.7k
Figure 14.5: Example of input connections
108 of 151
MAN085 04/2021 V1.3