14.6 I/O Connector
14.6.5
Single-ended Line Output
ISO_OUT0, ISO_OUT1 and ISO_OUT2 are single-ended isolated output.
Fig. 14.8 shows the connection from the ISO_OUT output to a TTL logic device.
LineOut0
LineOut1
LineOut2
2
1
12
11
CAMERA_PWR
CAMERA_GND
ISO_GND
17
Cam
era
Fi
rmw
are
13
14
10
Isolator
17-pin M12
I/O Connector
Camera
YOUR_POWER
&
YOUR_GND
YOUR_GND
&
YOUR_POWER
YOUR_GND
YOUR_POWER
R
R
ISO_OUT0
ISO_OUT1
ISO_OUT2 (high speed)
Figure 14.8: Example of output connection
Respect the limits of the opto-isolator in the connection to ISO_OUT. Maximal
ratings that must not be exceeded: voltage: 30 V, current: 0.5 A, power: 0.5 W.
(see also Fig. 14.9).
LineOut0
LineOut1
LineOut2
2
1
12
11
CAMERA_PWR
CAMERA_GND
ISO_GND
17
Cam
era
Fi
rmw
are
13
14
10
Isolator
17-pin M12
I/O Connector
Camera
YOUR_POWER
YOUR_GND
L
YOUR_POWER
L
D
D
1
D
2
Respect the limits of the output!
ISO_OUT0
ISO_OUT1
ISO_OUT2 (high speed)
Figure 14.9: Limits of ISO_OUT output
.
MAN085 04/2021 V1.3
111 of 151
Summary of Contents for Luxima DR4-D1280-L01-FB
Page 8: ...CONTENTS 8 of 151 MAN085 04 2021 V1 3...
Page 12: ...1 Preface 12 of 151 MAN085 04 2021 V1 3...
Page 42: ...4 Image Acquisition 42 of 151 MAN085 04 2021 V1 3...
Page 52: ...5 Counter Timer 52 of 151 MAN085 04 2021 V1 3...
Page 84: ...12 Pixel Data Processing 84 of 151 MAN085 04 2021 V1 3...
Page 94: ...12 Pixel Data Processing 94 of 151 MAN085 04 2021 V1 3...
Page 98: ...13 Precautions 98 of 151 MAN085 04 2021 V1 3...
Page 128: ...16 Troubleshooting 128 of 151 MAN085 04 2021 V1 3...
Page 134: ...19 Support and Repair 134 of 151 MAN085 04 2021 V1 3...
Page 136: ...20 References 136 of 151 MAN085 04 2021 V1 3...
Page 140: ...A Pinouts 140 of 151 MAN085 04 2021 V1 3...