4.7 Software Signal Pulse and User Output
4.7
Software Signal Pulse and User Output
The software signal pulse block contains eight general purpose registers which allow
generating internal pulse signals by software access. These pulse signals are internally
connected to following functions, where it can be used to start a procedure:
•
Acquisition Start Trigger
•
Acquisition End Trigger
•
Frame Start Trigger
•
Frame Burst Start Trigger
•
Frame Burst End Trigger
•
Exposure Start Trigger
•
Exposure End Trigger
•
Counter Trigger
•
Counter Event
•
Encoder Reset
•
Counter Reset
•
Timer Trigger
The user output block is an eight bit status register. The bits can be set to 0 or 1 by software.
The bits are available in the following firmware blocks/functions:
•
Counter Trigger
•
Counter Reset
•
Encoder Reset
•
LED S0 and S1
•
Line Out
MAN085 04/2021 V1.3