5.1 Counter
Exposure Start
Starts with the reception of the exposure start event.
Exposure End
Starts with the reception of the exposure end event.
User Output 0 ... 7
Starts and counts events as long as the selected user output bit is asserted.
When the counter is started, it ignores counter events as long as the corresponding user
output bit is deasserted (see Section 4.7).
Counter 0 ... 3 Start
Starts with the reception of the chosen counter start event.
Counter 0 ... 3 End
Starts with the reception of the chosen counter end event.
Timer 0 ... 3 Start
Starts with the reception of the chosen timer start event.
Timer 0 ... 3 End
Starts with the reception of the chosen timer end event.
Encoder
Starts with the reception of the encoder trigger event.
Action 0 ... 3
Starts with the receiption of the chosen action signal event.
Software Signal Pulse 0 ... 7
Starts with the reception of chosen software signal pulse event
(see Section 4.7).
Line Input
Starts when the specified counter trigger activation condition is met on the chosen
line.
Line input source has additionally an activation configuration, which needs to be set
accordingly. Following configuration values are available:
Rising Edge
Counter starts with the rising edge on the selected line input.
Falling Edge
Counter starts with the falling edge on the selected line input.
Both Edges
Counter starts with any edge on the selected line input.
Level High
Counter starts and is counting events as long as the level is high. When the counter
is started, it ignores counter events as long as the corresponding line input is low.
Level Low
Counter starts and is counting events as long as the level is low. When the counter
is started, it ignores counter events as long as the corresponding line input is high.
Activation configuration has only effect when line input is selected as a counter
trigger source, otherwise this configuration is ignored.
5.1.7
Counter Reset Source
The counter reset source selects the signal which will be the used to reset the counter. The
following signals sources are available:
Off
Disables the counter reset.
Counter Trigger
Resets with the reception of a trigger on the counter trigger source (see
Section 5.1.6).
Acquisition Trigger
Resets with the reception of the acquisition trigger.
Acquisition Start
Resets with the reception of the acquisition start event.
MAN085 04/2021 V1.3
47 of 151
Summary of Contents for Luxima DR4-D1280-L01-FB
Page 8: ...CONTENTS 8 of 151 MAN085 04 2021 V1 3...
Page 12: ...1 Preface 12 of 151 MAN085 04 2021 V1 3...
Page 42: ...4 Image Acquisition 42 of 151 MAN085 04 2021 V1 3...
Page 52: ...5 Counter Timer 52 of 151 MAN085 04 2021 V1 3...
Page 84: ...12 Pixel Data Processing 84 of 151 MAN085 04 2021 V1 3...
Page 94: ...12 Pixel Data Processing 94 of 151 MAN085 04 2021 V1 3...
Page 98: ...13 Precautions 98 of 151 MAN085 04 2021 V1 3...
Page 128: ...16 Troubleshooting 128 of 151 MAN085 04 2021 V1 3...
Page 134: ...19 Support and Repair 134 of 151 MAN085 04 2021 V1 3...
Page 136: ...20 References 136 of 151 MAN085 04 2021 V1 3...
Page 140: ...A Pinouts 140 of 151 MAN085 04 2021 V1 3...