3 Product Specification
3.3.3
Spectral Response
Fig. 3.5 and Fig. 3.6 show the quantum efficiency curve of the monochrome LUX1310 and
LUX2100 sensors from Luxima measured in the wavelength range from 350 nm to 1100 nm.
0%
10%
20%
30%
40%
50%
60%
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
1050
1100
Wavelength [nm]
LUX1310 Mono
Figure 3.5: Quantum efficiency (QE) [%] of the LUX1310 monochrome image sensors (with micro lenses
and cover glass)
0%
10%
20%
30%
40%
50%
60%
70%
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
1050
1100
Wavelength [nm]
LUX2810 Mono
Figure 3.6: Quantum efficiency (QE) [%] of the LUX2100 monochrome image sensors (with micro lenses
and cover glass)