background image

5

XP6000

Español

      

ESPECIFICACIONES

XP6000

Modo Estéreo (conduciendo ambos canales)

8 ohms FTC 20Hz-20kHz 0.1% THD

1420W

4 ohms FTC 20Hz-20kHz 0.1% THD

2180W

2 ohms FTC 20Hz-20kHz 0.1% THD

2600W

8 ohms EIA 1kHz 0.1% THD

1500W

4 ohms EIA 1kHz 0.1% THD

2400W

2 ohms EIA 1kHz 1% THD

3000W

Modo Bridge Mono

8 ohms FTC 20Hz-20kHz 0.1% THD

4000W

8 ohms EIA 1kHz 0.1% THD

4800W

4 ohms EIA 1kHz 1% THD

6000W

Todos lo Modelos

Distorsión (SMPTE-IM)

<0.02%

Distorsión (Típico) 20Hz-20kHz: 10dB bajo energía tasada

<0.02%

Distorsión (Típico) 1kHz y bajo: tada energía tasada

<0.02%

Respuesta en Frecuencia

20Hz-20KHz, 8 ohms, filtro LF bypass, +0/-1dB 

5Hz a 50kHz, 8 ohms, filtro LF bypass, +0/-3dB

Factor de Amortiguación

>250 @ 8 ohms

Ruido (desponderado)

100 dB debajo de salida tasada (20 Hz a 20 kHz, carga de 8 ohms)

Sensibidad de entrada

1.42 Vrms para 1000 watts en 8 ohms

Controles de panel frontal

Interruptor de energía AC, control de ganancia de CH1 & CH2 con 41 pasos

Controles de panel dorso

Interruptor DIP de 12-polos presenta encendido/apagado de filtro de paso 

alto, filtro de paso alto a 30/50 Hz, control de encendido/apagado de 

Limitador de Clip para cada canal e interruptores para seleccionar Modo 

Estéreo, Paralelo o Bridge. Interruptor de circuito de botón para cada 

canal. Interruptor deslizante para A Tirra/Flotante

Ganancia de Voltaje

41x (36dB)

Impedancia de Entrada

20 k ohms balanceada, 10 k ohms desbalanceada

Indicadores

Energía-Encendido: logo de Phonic ámbar; Paralelo: Icono de 

contraluz verde; Bridge: Icono de contraluz rojo; CLIP/LIM: LED Rojo; 

PROTECCIÓN: LED Amarillo, LED Verde para -10dB, -20dB y -40dB 

Luces de Señal

Entrada de Conectores

Jacks XLR, 1/4” TRS y tira de barrera

Salida de Conectores

Salidas de binding posts y speakon 

(cableado de speakon de Ch1 para biamp)

Enfriamiento

Ventilador de velocidad variable continuo, flujo de aire de atrás hacia 

adelante

Protección de Amplificador

Cortocircuito, circuito abierto, termal, utrasónica, y protección RF. Estable 

en cargas mal emparejadas

Protección de Carga

Enmudecimiento de encendido/apagado, perilla de salida de avería de DC

Circuito de Salida

Amplificador de Clase H

Requisitos de Energía  (depende de la región)

100-120VAC, 220-240VAC (+/- 10%), 50/60Hz (configurado de fábrica); 

modelo 120V requiere 20 amp

Interruptores de Circuito

Dos (uno para cada canal): modelos 100 y 120 V: 20 amp / 

modelos 230 V: 10 amp

Dimensiones (AnxAlxP)

482.6 x 133.5 x 376 mm (19" x 5.2" x 14.8")

Peso

28.2 kg (62.2 lbs)

Summary of Contents for XP6000

Page 1: ...User s Manual Manual del Usuario XP6000...

Page 2: ...POWER AMPLIFIER AMPLIFICADOR DE POTENCIA ENGLISH I ESPA OL II APPENDIX III V1 1 09 25 2017 English Espa ol XP6000...

Page 3: ...RES 1 INSTALLATION 1 FRONT PANEL DESCRIPTION 2 REAR PANEL DESCRIPTION 3 SPECIFICATIONS 6 APPENDIX DIMENSIONS 1 CONTENTS USER S MANUAL Phonic reserves the right to improve or alter any information with...

Page 4: ...ring lighting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord...

Page 5: ...ged housing INSTALLATION MOUNTING The power amplifier can be installed in a standard 19 inch equipment rack It requires 3 units of vertical rack space and secures to the rack cabinet with four rack mo...

Page 6: ...and reduce the gain Without power the fan cannot operate and the amplifier will require longer to reach a low enough temperature to restart 3 SIGNAL LEDS GREEN Each channel of the power amplifier fea...

Page 7: ...ce In addition to these users will also find barrier strip inputs Barrier strip inputs should be screwed down tight as to not let oxygen enter the connection These are best used in long term or perman...

Page 8: ...input of channel 1 to feed channel 2 also This allows channel 1 and 2 outputs to drive their own speakers independently however with the same source To set Parallel mode DIP switches 4 and 5 should b...

Page 9: ...pass filter on off high pass filter 30 50Hz Clip Limiter on off control for each channel and switches for selecting Stereo Parallel or Bridge Mode Push button circuit breaker for each channel Switch...

Page 10: ...n the dated sales receipt as evidence of the date of purchase You will need it for any warranty service No returns or repairs will be accepted without a proper RMA number return merchandise authorizat...

Page 11: ...CARACTERISTICAS 1 INSTALACI N 1 DESCRIPCI N DEL PANEL FRONTAL 2 DESCRIPCI N DEL PANEL DE DORSO 3 ESPECIFICACIONES 5 APPENDIX DIMENSIONES 1 Phonic se reserva el derecho de mejorar o alterar cualquier i...

Page 12: ...8 XP6000 Espa ol...

Page 13: ...MONTAJE Los amplificadores de potencia pueden ser instalados en un rack de equipo de 19 est ndar Esto requiere 3 unidades de espacio de rack vertical y asegurado al gabinete de rack con 4 tornillos d...

Page 14: ...y reduzca la ganancia Sin la energ a el ventilador no puede funcionar y el amplificador requerir m s tiempo para alcanzar a una temperatura suficientemente baja para recomenzar 3 LED DE SE AL VERDE Ca...

Page 15: ...e potencia ofrece conectadores de entrada XLR y TRS para su conveniencia de conexi n Los usuarios tambi n encontrar n entradas de tira de barrera Las entradas de la tira de barrera se deben atornillar...

Page 16: ...entar al canal 2 tambi n permitiendo las salidas de canal 1 y 2 conducen sus propios altavoces independientemente no obstante con la misma fuente Para setear a modo paralelo los interruptores DIP4y5de...

Page 17: ...or de Clip para cada canal e interruptores para seleccionar Modo Est reo Paralelo o Bridge Interruptor de circuito de bot n para cada canal Interruptor deslizante para A Tirra Flotante Ganancia de Vol...

Page 18: ...con la fecha de compra como evidencia de la fecha de compra Va a necesitar este comprobante para cualquier servicio de garant a No se aceptar n reparaciones o devoluciones sin un n mero RMA apropiado...

Page 19: ...Appendix Ap ndice 1 XP6000 DIMENSIONS DIMENSIONES...