9. FAN

Keep the front and rear vents 

clear to allow full airflow. Hot air will 

be drawn out the 

back of the amplifier, so it does not stay in the 

rack, and make sure plenty of cool air can enter the rack.

10. RESET BREAKER

With rated loads and output levels, the breaker should only shut 

down the amplifier in rare instances of catastrophic failure. The 
circuit breaker can also shut down the amplifier in cases where 
extremely low-impedance loads and high output levels result in a 
current draw that exceeds its rating.

11. POWER CORD

All units are shipped with an appropriate plug and cord for the 

required  AC  voltage.  This  product  is  equipped  with  a  3-wire 

grounding type plug. This is a safety feature and should not be 
defeated. Check the AC voltage before connecting the plug.

12. CHASSIS GROUNDING CONNECTING POINT

Please refer to your local safety code for proper grounding.

13. OUTPUT CONNECTORS

A pair of versatile binding posts and Speakon connectors are 
provided for output connection to each channel. Loudspeakers 
can be easily connected using banana plugs, spade lugs, bare 
wires or Speakon connector. Spade lugs and bare wires should 
both be screwed down tightly to avoid a short circuit. The 
Speakon connector for channel 1 includes channel 1, channel 
2 and bridged mono pin connecting points. A pin out information 
could be foundbeside the Speakon connector.

14. INPUT CONNECTORS

The  power  amplifier  offers  XLR  and  TRS  input  connectors  for 

your connecting convenience. In addition to these, users will also 

find  barrier  strip  inputs.  Barrier  strip  inputs  should  be  screwed 
down tight as to not let oxygen enter the connection. These are 

best used in long term or permanent installations.

15. GROUNDING - FLOATING SWITCH

This switch allows the circuit and chassis grounding to be 

separated  in  case  of  a  grounding  conflict.  In  normal  use,  the 

switch should be in the grounding on position. Lifting the 

grounding (to what is called the floating position) may resolve the 
ground conflict, but it means that circuit grounding depends on 
other  connected  equipment.  Deficiencies  in  other  components’ 
grounding  will  affect  the  sound  quality  and  cause  a  grounding 

loop hum. For the best combination of safety and performance, 
it is highly recommended to set the switch at the “grounding on” 
position.

16. MODE SWITCHES

This series of DIP switches allows users to activate a number of 
functions on channels 1 and 2. Such features include high pass 

filter, limiters, and operating mode.

HPF (High Pass Filter)

These switches (DIP switches 1 and 2 
for channel 1, 11 and 12 for channel 2) 
can activate a 30Hz or 50Hz high pass 
filter,  which  will  roll  off  signals  below 
either 30 or 50Hz. This improves sub 

bass performance by limiting sub bass 
cone motion. It will also make more 
power available for your speaker's 
rated frequency range.

LIMITER ON/OFF

These  DIP  switches  (DIP  switch  3 
for  channel  1  and  10  for  channel  2) 

allow you to activate the speak limiter 

circuit  built  into  the  power  amplifier. 

This function will reduce distortion and 

protect speakers. To activate the built-
in  limiters,  DIP  switches  3  (channel  1 
limiter) and 10 (channel 2 limiter) should 

be set to the right position.

14

15

16

13

10

10

11

12

Summary of Contents for XP6000

Page 1: ...User s Manual Manual del Usuario XP6000...

Page 2: ...POWER AMPLIFIER AMPLIFICADOR DE POTENCIA ENGLISH I ESPA OL II APPENDIX III V1 1 09 25 2017 English Espa ol XP6000...

Page 3: ...RES 1 INSTALLATION 1 FRONT PANEL DESCRIPTION 2 REAR PANEL DESCRIPTION 3 SPECIFICATIONS 6 APPENDIX DIMENSIONS 1 CONTENTS USER S MANUAL Phonic reserves the right to improve or alter any information with...

Page 4: ...ring lighting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord...

Page 5: ...ged housing INSTALLATION MOUNTING The power amplifier can be installed in a standard 19 inch equipment rack It requires 3 units of vertical rack space and secures to the rack cabinet with four rack mo...

Page 6: ...and reduce the gain Without power the fan cannot operate and the amplifier will require longer to reach a low enough temperature to restart 3 SIGNAL LEDS GREEN Each channel of the power amplifier fea...

Page 7: ...ce In addition to these users will also find barrier strip inputs Barrier strip inputs should be screwed down tight as to not let oxygen enter the connection These are best used in long term or perman...

Page 8: ...input of channel 1 to feed channel 2 also This allows channel 1 and 2 outputs to drive their own speakers independently however with the same source To set Parallel mode DIP switches 4 and 5 should b...

Page 9: ...pass filter on off high pass filter 30 50Hz Clip Limiter on off control for each channel and switches for selecting Stereo Parallel or Bridge Mode Push button circuit breaker for each channel Switch...

Page 10: ...n the dated sales receipt as evidence of the date of purchase You will need it for any warranty service No returns or repairs will be accepted without a proper RMA number return merchandise authorizat...

Page 11: ...CARACTERISTICAS 1 INSTALACI N 1 DESCRIPCI N DEL PANEL FRONTAL 2 DESCRIPCI N DEL PANEL DE DORSO 3 ESPECIFICACIONES 5 APPENDIX DIMENSIONES 1 Phonic se reserva el derecho de mejorar o alterar cualquier i...

Page 12: ...8 XP6000 Espa ol...

Page 13: ...MONTAJE Los amplificadores de potencia pueden ser instalados en un rack de equipo de 19 est ndar Esto requiere 3 unidades de espacio de rack vertical y asegurado al gabinete de rack con 4 tornillos d...

Page 14: ...y reduzca la ganancia Sin la energ a el ventilador no puede funcionar y el amplificador requerir m s tiempo para alcanzar a una temperatura suficientemente baja para recomenzar 3 LED DE SE AL VERDE Ca...

Page 15: ...e potencia ofrece conectadores de entrada XLR y TRS para su conveniencia de conexi n Los usuarios tambi n encontrar n entradas de tira de barrera Las entradas de la tira de barrera se deben atornillar...

Page 16: ...entar al canal 2 tambi n permitiendo las salidas de canal 1 y 2 conducen sus propios altavoces independientemente no obstante con la misma fuente Para setear a modo paralelo los interruptores DIP4y5de...

Page 17: ...or de Clip para cada canal e interruptores para seleccionar Modo Est reo Paralelo o Bridge Interruptor de circuito de bot n para cada canal Interruptor deslizante para A Tirra Flotante Ganancia de Vol...

Page 18: ...con la fecha de compra como evidencia de la fecha de compra Va a necesitar este comprobante para cualquier servicio de garant a No se aceptar n reparaciones o devoluciones sin un n mero RMA apropiado...

Page 19: ...Appendix Ap ndice 1 XP6000 DIMENSIONS DIMENSIONES...

Page 20: ......

Reviews: