background image

Instruction & Maintenance Manual

Sheet 1.48

Phoenix

 ‘SPC10e’

 Self Propelled Metering Chipping Spreader

03/12

MET

IMP

RPM

DELAY

M Total
Ft  Total

M Part
Ft  Part

km/h

mph

mpm

Ft /Min

Summary of Contents for SPC10e

Page 1: ...ce Manual Sheet 1 21 Phoenix SPC10e Self Propelled Metering Chipping Spreader 03 12 INSTRUCTION MANUAL For the Ph nix SPC10e Self Propelled Metering Chipping Spreader Section 1 2 Drive Controls Engine...

Page 2: ...Instruction Maintenance Manual Sheet 1 22 Phoenix SPC10e Self Propelled Metering Chipping Spreader 03 12 Blank...

Page 3: ...moving including use of the normal access steps AT NO TIME leave the operator s position with the machine still moving ALWAYS place drive control to neutral and apply the parking brakes ALWAYS ENTER E...

Page 4: ...t hand without particularly ensuring the foot brake can be reached in an emergency IMPORTANT Ensure the column is locked and secure BEFORE moving off DO NOT attempt to adjust the column with the machi...

Page 5: ...ion the area immediately behind the machine may not be fully visible When reversing either lower the folding sides to give make this area fully visible or move the machine one metre forward to check t...

Page 6: ...ew immediately outward of the front spread hopper and back along the side including the extension spreading hopper when out Adjust so the area immediately to the side of the machine side of front spre...

Page 7: ...obstruct the reverse warning bleeper as this may effect the sound level emitted Daily before starting to use the machine the reverse warning bleeper MUST be tested to ensure its operation There is no...

Page 8: ...Instruction Maintenance Manual Sheet 1 28 Phoenix SPC10e Self Propelled Metering Chipping Spreader 03 12 Controls Layout Front Console H H...

Page 9: ...ttle control switch PERKINS front console Engine throttle control switch JCB RH console Parking Brake RH console Brake foot pedal service brake floor Steering control wheel front console Joystick with...

Page 10: ...tor Air pressure low warning Additional warning lights ONLY for JCB Engine Electrical charge warning RH Console Will light if charge circuit is not re charging battery Check charging circuit battery c...

Page 11: ...immediate attention The display will show a warning hexagon in the centre of the centre When an engine fault appears the display will show a warning message such as HIGH WATER TEMPERATURE To return to...

Page 12: ...nsmission Oil Pressure This illuminates when a loss of pressure to the transmission gearbox occurs In the first instance put the transmission into LOW speed range and move the machine to a safe locati...

Page 13: ...rpm Operating Travel speed 1800 rpm Throttle speeds are automatically set by a three position switch Other speeds are not possible Start the engine To start the engine the operator MUST set the engin...

Page 14: ...er A cold start aid is fitted refer to the Perkins manual for further information Do not use Ether or Ki gas as a starting aid To use cold start turn ignition key back for 10 seconds Cold start light...

Page 15: ...Instruction Maintenance Manual Sheet 1 35 Phoenix SPC10e Self Propelled Metering Chipping Spreader 03 12 Control Layout Side Console Joystick JCB ENGINE VERSION...

Page 16: ...ve key from Battery Isolator Isolate the battery when leaving the machine overnight or for longer periods as the engine management will continue to drain battery power when the ignition is off IMPORTA...

Page 17: ...ansmission allows for a very smooth operation i e snatch free take up and an infinitely variable travelling speed at constant engine speed in either of the two speed ranges Optionally a MIDRANGE speed...

Page 18: ...Instruction Maintenance Manual Sheet 1 38 Phoenix SPC10e Self Propelled Metering Chipping Spreader 03 12 Control Layout Side Console Joystick PERKINS ENGINE VERSION...

Page 19: ...HIGH speed range 0 to 26 kph HIGH MEDIUM range 0 to 16 kph Hillclimbing seed LOW and HIGH ranges are selected by a switch on the front console with hare marking In LOW range the tortoise warning light...

Page 20: ...avel from 0 to 26 kph This is the normal setting for travelling Switching ON MidRange switch illuminated restricts the top speed to 16kph speed range is 0 to 16 kph In this Medium High the machine is...

Page 21: ...l position To increase reverse speed move the joystick back further To slow and stop the joystick should be moved forward to its neutral position The joystick can be moved into any position and will r...

Page 22: ...without the joystick being in neutral the joystick function will be disabled The drive will not start until the joystick has been returned to the NEUTRAL position to reset the joystick function To cha...

Page 23: ...evice will be activated The overload will bring the machine to a controlled stop regardless of joystick position Once the machine is stationary the power limit on the engine will be released For the o...

Page 24: ...ing effort Otherwise only when the joystick has already been returned to its neutral position use the brakes to bring the machine to a halt IMPORTANT The hydrostatic transmission will drive AGAINST th...

Page 25: ...PARK BRAKE warning light goes out 3 The Park Brake is released and the machine will immediately be moved by inputs of the Joystick 4 IMPORTANT The joystick will be disabled if not in its neutral posit...

Page 26: ...or working on the brake system Refer to the maintenance manual before manually releasing the Park Brake Power Failure If an electrical power failure occurs the joystick will stop controlling the drive...

Page 27: ...ckly than the oil flow available Once you stop steering or slow the rate of turning normal operation will immediately return IMPORTANT Do not steer whilst the machine remains stationary This places co...

Page 28: ...Instruction Maintenance Manual Sheet 1 48 Phoenix SPC10e Self Propelled Metering Chipping Spreader 03 12 ME T IMP R PM DE LAY M T otal Ft T otal M P art F t P art km h mph mpm Ft Min...

Page 29: ...d whenever the machine is motion The r p m of the centre FeedRoller RPM The delay feature will allow for the start stop of the application of aggregate to be a straight line across the machines path D...

Page 30: ...nction FeedRollers When the screen shows above the delay function the display will show OFF when the delay function is not operative or ON when the delay function is in use To change between OFF ON pr...