Operation
61-900040-000
Rev. Date:
01/22
3-31
Table 3- 110 continued
CLEANER OPERATION
OIL OPERATION
BUFF OPERATION
Travels toward the
approach until the counter
wheel counts down to 1
foot from the foul line.
Applies oil until the counter
wheel counts down to 1 foot
from the foul line.
Brushes the existing oil until
the counter wheel counts
down to 1 foot from the foul
line.
Turns off the drive motor.
Turns off the oil transfer
roller motor.
Turns off the buffer motor
and retracts buffer.
Turns off the drive motor.
Turns off the buffer motor
and retracts buffer.
Turns off the drive motor.
Second Pass:
Cleaner
system does not operate.
Second Pass:
Performs the
above steps out to the second
pass distance settings.
Second Pass:
Performs the
above steps out to the second
pass distance settings.
NOTE
Though the vacuum, buffer, and drive motors are turned off, the Phoenix LT4 is still
powered on. The machine will de-energize the vacuum head solenoids and lower the
vacuum head if left idle for more than 5 minutes. Cycle the power switch to reset.
Once the Phoenix LT4 has returned to the approach and turned off the motors for the
operations selected, it can be moved to the next lane or press the POWER switch to turn
off the machine. For information about storing the Phoenix LT4, refer to Section 4 -
Maintenance and Adjustments
. It is best to power off the machine on the approach.
Otherwise, the vacuum head will drop onto the lane. When the machine is pulled onto the
approach with the vacuum head down, the squeegee and agitator foam will be dragged