AXL F PSDO8/3 1F
38
PHOENIX CONTACT
105739_en_04
The following are specified for each example:
–
Basic specifications
The table specifies the main data for the example.
–
Device diagnostics and behavior of the module in the event of an error
Diagnostic capability depends on the parameterization.
If a message is transmitted to the controller in the event of an error, the message is
specified in the tables. Information on the relevant error code as well as possible
solutions and information as to whether the error message must be acknowledged: see
Section 8 “Errors: messages and removal” on page 51.
–
Typical parameterization
The table illustrates an example of all the parameters for the specified assignment.
Key for tables in this section:
Errors (cross-circuits, short circuits) which can be prevented by correct installation (e.g.,
protected cable installation, isolated cable installation, double insulation, use of ferrules) are
not described in the tables.
Only errors between outputs, which are on the same connector, are described. For
example, in the event of correct installation, cross-circuits with outputs of other connectors
cannot occur.
6.2
Notes on the protective circuit of external
relays/contactors (freewheeling circuit)
Figure 6-1
Example of the freewheeling circuit for an external relay
Observe the following measures:
•
Limit the voltage induced on circuit interruption to < -15 V (e.g., with RC elements,
suppressor diodes or varistors).
•
Please note that the freewheeling circuit affects the fall time and the service life of the
contactor.
•
Please observe the specifications of the relay manufacturer when dimensioning the
relay protective circuit.
Table 6-1
Parameterization tables
Representation
Meaning
Bold
Mandatory setting
Normal
Typical setting, another setting is possible depending on the
application
–
Not evaluated
K1
69400021
Summary of Contents for Axioline F
Page 1: ...User manual Axioline F safety module with safe digital outputs UM EN AXL F PSDO8 3 1F ...
Page 8: ...AXL F PSDO8 3 1F 8 PHOENIX CONTACT 105739_en_04 ...
Page 22: ...AXL F PSDO8 3 1F 22 PHOENIX CONTACT 105739_en_04 ...
Page 32: ...AXL F PSDO8 3 1F 32 PHOENIX CONTACT 105739_en_04 ...
Page 36: ...AXL F PSDO8 3 1F 36 PHOENIX CONTACT 105739_en_04 ...
Page 46: ...AXL F PSDO8 3 1F 46 PHOENIX CONTACT 105739_en_04 ...
Page 50: ...AXL F PSDO8 3 1F 50 PHOENIX CONTACT 105739_en_04 ...
Page 62: ...AXL F PSDO8 3 1F 62 PHOENIX CONTACT 105739_en_04 ...
Page 64: ...AXL F PSDO8 3 1F 64 PHOENIX CONTACT 105739_en_04 ...
Page 84: ...AXL F PSDO8 3 1F 84 PHOENIX CONTACT 105739_en_04 ...
Page 86: ...AXL F PSDO8 3 1F 86 PHOENIX CONTACT 105739_en_04 ...