Hardware installation PSI-MODEM-SHDSL/ETH
104273_en_01
PHOENIX CONTACT
45
4.3.4
Connecting switching outputs
Figure 4-11
Digital switching outputs
The Ethernet extender has two digital switching outputs.
–
DO switching output, digital (24 V, open)
–
DIO switching output, digital (24 V, open)
You can set the switching outputs via the PSI-CONF configuration software.
4.3.4.1
Default setting
Connecting
•
Connect the cable to the corresponding screw terminal block.
NOTE: Malfunction
If voltage is supplied via USB or by means of DIN rail connectors, the switching outputs
(DO/DIO)
cannot
be used. The switching outputs only function if the voltage is supplied
via the COMBICON connectors.
NOTE: Malfunction
The switching outputs have to be connected to a load between 220
Ω
and 100 k
Ω
.
DSL A
DO = 24 V
Good to very good connection
DO = open
No or only moderately good connection
DSL B
DIO = 24 V
Good to very good connection
DIO = open
No or only moderately good connection
DO DIO