Mixing pump RITMO L Eco Overview - Operation
Removal of clogging in hoses
12 April 2019 13:43:00
53
46.2 Blockage cannot be cleared
2
1
Fig. 79: Check mortar pressure
DANGER!
Overpressure on the machine!
When opening machine parts they can open in an
uncontrolled manner and injure the operator.
Open the mortar hoses only when the pressure at
the mortar pressure gauge (1) has dropped to "0
bar".
DANGER!
Danger of injury from discharged mortar!
Discharged mortar may lead to injuries to eyes and
face.
Therefore:
Always wear protective goggles.
Always position yourself in such a way that you
are not hit by the mortar being discharged.
1. Cover coupling connections with tear-proof film.
2. Slightly loosen both screws (2) at the tie rod slowly so that the
remaining pressure can escape completely.
3. As soon as the pressure has dropped to "0" bar, tighten the
screws (2) again.
3
Fig. 80: Loosen coupling
NOTE!
Clean the mortar hoses and spraying gun
immediately.
4. Loosen cam leaver (3) and hose connections.
5. Dislodge the blockage by tapping or shaking at the place where
the blockage is located.
6. If required, insert a purging hose into the mortar hose and flush
out the material (PFT purging hose art. no. 00113856).