Mixing pump RITMO L Eco Overview - Operation
Mortar pressure gauge
36
12 April 2019 13:43:00
30.8 Open the protection grille
Fig. 48: Open the protection grille
1. Loosen nuts (1) of the protection grille.
2. Tilt the protection grille with motor (2) backwards.
30.9 Close the protection grille with motor
Fig. 49: Open the protection grille
NOTE!
The material container must be dry inside.
1. Insert mixing shaft (1).
2. Close the protection grille with motor (2).
3. Firmly tighten the nuts (3) of the protection grille.
4. Connect the motor connection cable to the gear motor.
Fig. 50: Fit of the mixing shaft
NOTE!
When inserting the mixing shaft (1)
ensure that the mixing shaft engages
with the head of the rotor (4) and grips
properly into the hauling bracket (5)
when closing the motor flange.
31 Mortar pressure gauge
Fig. 51: Mortar pressure gauge
DANGER!
Operating pressure too high!
Machine parts can open in an uncontrolled manner
and injure the operator.
Do not operate the machine without mortar
pressure gauge.
Use only mortar hoses with a permissible
operating pressure of at least 40 bar.
The burst pressure of the mortar hose must
reach at least 2.5 times the value of the
operating pressure.
2
1
2
1
3
1
4
5