Mixing pump RITMO L Eco Overview - Operation
Putting the machine into operation
38
12 April 2019 13:43:00
35 Putting the machine into operation
35.1 Check consistency of mortar
Fig. 54: Consistency checking tube
1. Connect consistency checking tube at the mortar pressure
gauge.
2. Place a bucket or pan under the consistency checking tube.
Article number: 20104301 Consistency checking tube 25 female-
part piece
35.2 Switching onRITMO L Eco with material
1
2
3
Fig. 55: Switching on
1. Turn the selector switch (1) clockwise to position "FWD".
2. The machine starts.
NOTE!
During daytime operation, switch the machine on or
off only at the selector switch (1).
3. Adjust the potentiometer (2) for motor speed / material quantity
as required.
4. Check material consistency at the consistency checking tube
(3).
5. Switch off the machine at selector switch (1) (middle position).
6. Remove consistency checking tube and clean it.
36 Mortar hoses
36.1 Prepare mortar hoses
Fig. 56: Prepare mortar hose
1. Connect the cleaner coupling (1) to the tap (2).
2. Connect mortar hose (3) to the tap.
3. Open the tap (2) and soak the mortar hose (3).
4. Remove mortar hose and cleaner coupling again and separate.
5. Remove all the water from the mortar hose.
6. Pre-lubricate the mortar hose with about 1 litres of wallpaper
paste.
2
1
3