Mixing pump RITMO L Eco Overview - Operation
Brief description of RITMO L Eco
12 April 2019 13:43:00
25
Fig. 24: Suction strainer with filter screen
The end of the suction line (3) has to be equipped with a suction
strainer with filter screen and built-in non-return valve.
We recommend an additional filter for fine particles in the suction
line.
NOTE!
The flow rate of the pump decreases with
increasing length of the suction line. Connect the
booster pump as close as possible to the water
sampling point (pressure is better than suction).
If all these points have been observed the pump can be switched
on. Depending on the length of the suction line, the suction time
can be up to a few seconds. If the pump does not deliver after a
short time, this might be due to the following reasons:
There is still air in the pump and it has to be vented completely
once again.
The suction line has a leak and the pump draws air.
The suction strainer is clogged.
There is a kink in the suction hose.
The maximum suction height is exceeded.
Caution!
The pump must not run dry to avoid any damage.
22 Brief description of RITMO L Eco
Fig. 25: RITMO L Eco
The compact mixing pump RITMO L Eco with 230 V AC drive,
specially developed for pumping, spraying and applying of dry
mortar, pasty materials for machine use and much more up to 2
mm grain size.
Depending on the requirement, the pump capacity can be adjusted
electronically in a step-less manner.
The machine is made up of portable individual components, which
facilitate speedy and convenient transport when the dimensions
are manageable and the weight is at a low level.