Mixing pump RITMO L Eco Overview - Operation
Stopping in case of an emergency RITMO L Eco
12 April 2019 13:43:00
43
Fig. 67: Mortar hose
Article number: 00021103
Description: RONDO mortar pressure hose 25 mm 5 m
with hydraulic connection
Article number: 00021100
Description: RONDO mortar pressure hose 25 mm 10 m
Hydraulic connection
Article number: 00037491
Description: RONDO 25 mm 10 m with rotary coupling
Additional mortar hose accessories available at www.pft.eu
39.2 Process pasty material
Fig. 68: Blind cover
1. Detach connector of air compressor from the on/off switch.
2. Remove the water hose (1) from the mixing tube and close the
mixing tube using blind cover.
3. Connect compressed air hose (2) at the air manifold.
4. The water hose (3) of the water supply network must be
connected.
5. Close the needle valve (4) at the water manifold completely.
Fig. 69: Pasty material
6. The pasty material can be filled in the material hopper.
7. Turn the selector switch (5) clockwise to position "FWD” (machine
starts).
8. Adjust the potentiometer (6) for motor speed / material quantity as
required.
40 Stopping in case of an emergency RITMO L Eco
40.1 Stop function
Stopping in case of an emergency
In dangerous situations machine movements have to be stopped
as quickly as possible, and the power supply has to be
disconnected.
Fig. 70: Stopping
In case of danger proceed as follows:
1. Actuate the stop function (1) at the on/off switch.
2. With the help of the stop function, secure the hinged lid against
start-up using a lock (2).
3. Disconnect the power supply by removing the connection cable
4. Inform responsible person at the operational site.
5. If necessary, call for medical assistance and a fire brigade.
6. Recover persons from the danger zone, initiate First Aid
measures.
7. Keep access routes free for emergency vehicles.
1
2
3
6
5
1
2