Adjustment
122
Group
P
arameter
Description
Set
ting
range
Set v
alue
200
206
End stitch condensation stitch count
1 - 20
5
207
Angle seam end [°]
0 - 90
30
208
Angle seam end stitch count
1 - 9
5
209
Basting seam starting stitch length [0.1 mm]
10 - 60
20
210
Basting seam starting stitch count
1 - 9
3
211
Basting seam end stitch length [0.1 mm]
10 - 60
40
212
Basting seam end stitch count
1 - 9
4
213
Starting point correction, 2-point [0.1 mm]
0 – 150
120
214
Short thread trimmer confi guration
0 – not attached
1 – attached and activated
(Prog Out1 and Prog
Out2 used! )
0
215
Stacker Variant 3586 25/01
0 old, 1 new
1
300
301
NIS (carriage start) [°], see
chapter 13.12.03
80 – 150
110
302
Cover thread carrier position t.d.c. [°]
70 – 90
76
303
Thread trimming position on [°]
The time at which the pulse for the thread trim-
ming is given to the thread trimming valve is
changed (° = degrees after t.d.c. needle bar).
160 – 360
200
304
Reverse rotation position [°]
0 - Cover thread car-
ried position t.d.c.
17
305
Electric clamp on [°]
100 – 185
150
306
Electric clamp off [°]
190 – 260
240
307
Position thread tension open when trimming [°]
200° – 360
250
308
Pos. elec. thread trapper on during thread cut
0° – 360°
341°
400
401
Time for blowing out [0,01s]
10 – 250
30
402
Start delay for retracting workholder bar [0,01s]
0 - 250
0
403
Fabric blowdown time [0,01s]
0 - 250
0
404
Start delay after pedal start [0,01s]
0 - 250
30
500
501
Maximum speed
200 - 4500
4500
502
Bartack speed (reduced speed)
200 - 4500
4500
503
Cutting speed (positioning speed)
100 - 250
200
504
Speed of the slow starting stitches
200 - 2000
1000
505
Slow starting stitches
The number of stitches that should be performed
at a reduced speed when sewing is changed.
0 – 99
2
506
Basting seam speed
200 - 1000
1000
Summary of Contents for 3586-22/02
Page 42: ...Set up 42...