Adjustment
12 - 32
A
- Needle thread cutter / clamp
B
- Middle knife
C
Interfacing feed
D
- Stacker (time)
E
- 2
nd
service level (code entry required, 8 x “9”)
F
- back to basic display
Closing order of the flap clamps (see
Chapter 7.05 Foot switch)
Closing order of the main clamps (see
Chapter 7.05 Foot switch)
A
- Clamp speed and clamp insertion to seam beginning
B
- Bartacking
C
-
(R1)
Clamp speed, position for cutting needle thread and path to first mitre cut
(R2)
Clamp speed and path to second mitre cut
D
- Speed “reverse clamp” and rear end position of the clamps
H
-
Setting safety length flap
Encoder
– seam length correction
12
.05.29
Summary of the functions in the service menu
Select the service menu with the Technics/Service function .
Sensor and stacker on/off (see
Chapter 7.05 Foot switch)
Vacuum and trouser stamp on/off (see
Chapter 7.05 Foot switch)
Needle thread monitor on/off (see
Chapter 7.05 Foot switch)
Bobbin thread counter on/off
Service settings
(code entry required, 8 x “1”)
Output test
Backtacking settings
Back to basic display
Select/reset piece counter
Display setting (language(contrast)
Adjustment flaps / main clamps
Machine information
Summary of Contents for 3582-2/01
Page 89: ...Register 08 Contents Chapter Page 13 Pneumatics circuit diagramc 13 1 Circuit diagrams 13 8...
Page 96: ...13 7 Pneumatics circuit diagram Part 6 Version 01 01 2002 a0 A0 14 14 Q2 5 Y14 Q2 6 Option Y15...
Page 98: ...13 9 Version 01 01 2002 Circuit diagrams...
Page 99: ...13 10 General Plan Inputs Version 01 01 2002...
Page 100: ...13 11 Version 01 01 2002 General Plan Inputs Outputs...
Page 101: ...13 12 General Plan Clamp Drive Version 01 01 2002...
Page 102: ...13 13 Version 01 01 2002 General Plan Quick Mini Stop...
Page 103: ...Notes...