Adjustment
12 - 25
71-064
12
.05.22
Distance of both main clamps from the folding unit
Requirement
Both main clamps
1
and
5
should be
1. Parallel to the folding unit over their entire length and
2. At a distance of
0.5 mm
from the folding unit.
Left main clamp
●
Align main clamp
5
(screws
6
) in accordance with
requirement 1
.
●
Insert folding unit for double piping.
●
Adjust adjustment ring
7
(screws
8
) in accordance with
requirement 2
.
●
Insert folding unit for single piping.
●
Making sure that main clamp
1
is touching adjustment ring
9
, adjust adjustment ring
9
(screws
10
) in accordance with
requirement 2
.
Right main clamp
●
Align main clamp
1
(screws
2
) in accordance with
requirement 1
.
●
Adjust adjustment rings
3
(screws
4
) in accordance with
requirement 2
.
Fig. 12 - 24
2
3
3
4
4
1
6
7
8
9
10
5
71-050
0,5 mm
0,5 mm