Adjustment
12 - 6
71-031
Fig. 12 - 04
Needle height
●
Without twisting it, adjust the needle bar
(screw
3
) in accordance with the
requirement 1
.
Hook to needle clearance
●
Loosen the screws of the hook gear drive through the installation holes (arrows).
●
Adjust the hook bearing (screws 4) in accordance with
requirement 2
, taking care that the
needle is not deflected by needle guard
5
.
●
Control the movement of the lifting eccentric.
Needle guard
●
Bring the needle bar into the needle rise position by turning the balance wheel.
●
Align needle guard
5
in accordance with
requirement 3
.
1,0 mm
4
4
4
4
73-013
0,05 - 0,1 mm
5
71-032
3