Adjustment
12 - 3
71-029
12
.05.01
Preliminary adjustment of the needle height
Requirement
When the needle bar is at t.d.c. there should be a distance of approx.
15 mm
between the
needle points and the needle plate.
●
Without twisting it, adjust needle bar
1
(screw
2
) in accordance with the
requirement
.
Fig. 12- 02
2
1
71-027
15 mm