Adjustment
13
.06.21
Counter presser position
Requirement
1. When the needle penetrates, it must be centered in the needle hole in the counter
presser
5
.
2. When the needle bar is at BDC, the counter presser
5
must be at its front point of
reversal and with the back edge of the needle hole resting against the needle.
13 - 24
Fig. 13 - 23
3
6
1
2
4
4
5
●
Turn crank
1
(screw
2
) so that the counter presser
3
travels
0.6 - 1 mm
, and the needle,
when it penetrates, is centered in the needle hole in the counter presser
3
.
●
Loosen screws
4
just enough so that the eccentric
5
is difficult to turn on the shaft.
●
Bring needle bar to BDC.
●
Turn eccentric
5
until the counter presser
3
is in its back point of reversal and tighten
screws
4
.
●
Move counter presser
3
carrier (screws
6
) until the the back edge of the needle hole of
the counter presser
3
is resting against the needle (see arrow).
Move counter presser
3
carrier (screws
6
) until the the back edge of the needle
hole of the counter presser
3
is resting against the needle (see arrow).