Mounting and commissioning the machine
9
.02.01
Turning the machine on/off
9 - 3
Fig. 9 - 04
Fig. 9 - 05
●
Open knob
1
.
●
Check air pressure on pressure gauge
2
, and regulate air compression with adjusting
knob
3
, if necessary.
●
If necessary, release EMERGENCY OFF switch
4
by pulling up on it.
●
Turn master switch
5
to "
ON
".
●
Press the
On key
on the control panel of the folder. The machine is now in the
INPUT
operation mode.
When the machine is commissioned, the zero point must first be checked and/
or adjusted (see
chapter 9.02.02 Adjusting zero point
).
●
To turn off the machine, turn master switch
5
to "
OFF
" and close knob
1
.
In emergencies, the machine can be stopped immediately by pressing down
the EMERGENCY OFF switch
4
.
3
4
1
2
5