129
Control
Display
Description
ERROR: 401
Text file cannot be opened
ERROR: 402
Error in read text file
ERROR: 403
Error when assigning memory space for the texts
ERROR: 501
Error when opening the file "pikto.hex" or "vorlagen.hex"
ERROR: 502
No ACK from control panel
14
.02.02
CAN errors
Error byte
Description
bit7
End phase error (short circuit)
bit6
-
bit5
-
bit4
Receive status (wait for input object)
bit3
Transmit status (send output object)
bit2
Transmit status
bit1
Node time-out
bit0
Node active
14
.02.03
Stitch generation
Display
Description
1
Start backtack too large
2
Start backtack too large
3
Starting stitch condensation too large
4
Incorrect bartack type
5
Bartack length > 6 mm
11
x-coord. > xsewing area_max
12
x-coord. < xsewing area_min
13
y-coord. > ysewing area_max
14
y-coord. < ysewing area_min
15
Bartack starting point is above L2 and ARSZ < 2