Adjustment
87
Fig. 13 - 26
3
3
64-083
1
2
13
.28
Adjusting the reed switch
Requirement
When parameter "610" is set at "1" and the machine is in the needle rise position, the
reed switch
1
should operate exactly at the moment when the tip of the retaining finger
3
is positioned at the centre of the needle.
●
Switch on the machine, set parameter "610" at "1" and bring the needle bar into the
needle rise position.
●
Loosen screw
1
and move the reed switch 2 completely to the right.
●
Place the point of the retaining finger at the centre of the needle and hold it in this
position.
●
Move reed switch
2
to the left, until reaching the switch point.
●
Fasten screw
1
.
●
Check the switch status of reed switch
2
with parameter "602" (position 4).
●
Switch off the machine.