111
Adjustment
Group
Parame-
ter
Description
Setting
range
Set
value
200
205
Missed stitch detection
I = OFF, II = ON
I, II
I
206
Missed stitch detection threshold
0 - 999
120
207
Suppressed stitches of missed stitch de-
tection function
0 - 9
6
208
1 – 120 =
Display thread size of last program (max.
120 stitches)
0 =
Display calculated optimum threshold
(for input in para. 206)
0 -120
209
Air jet
I = OFF, II = ON
Caution! When a thread wiper is at-
tached, the air jet must be switched off!
I, II
I
210
Air jet starting time [s]
0 - 10
1
211
Initialise clamp when sewing starts
I = OFF, II = ON
I, II
I
400
401
Delay for raising clamp [s]
0,00 - 1,50
0
402
Start delay after lowering clamp [s]
0,00 - 1,50
0
403
Delay before thread trimming [s]
(switching time to thread wiper forwards)
0,00 - 2,00
0,06
404
Thread trimming time [s]
0,00 - 2,00
0,06
405
Time between “thread clamp closed”
and “thread wiper on” [s]
0,00 - 2,00
0,10
406
Response time for thread puller [s]
0,00 - 2,00
0,30
407
Response time until thread wiper back [s]
0,00 - 4,00
0
408
Time for added feature clamp [s]
0,00 - 1,50
1
409
Delay after rotary cylinder on/off [s]
0,00 - 1,50
0,10
410
Delay after loading cylinder up/down [s]
0,00 - 1,50
0,10
Summary of Contents for 3307-1 SERIES
Page 127: ...127 Circuit diagrams Version 13 11 06 91 191 512 95 Teil 1...
Page 128: ...128 Circuit diagrams Version 13 11 06 91 191 512 95 Teil 2...
Page 129: ...129 91 191 512 95 Teil 3 Version 13 11 06 Circuit diagrams...
Page 130: ...130 Circuit diagrams Version 13 11 06 91 191 512 95 Teil 4...
Page 131: ...131 91 191 512 95 Teil 5 Version 13 11 06 Circuit diagrams...