39
9.1
1
1.1
3.2
RCS Climbing Device and Hydraulics
Assembly Instructions
Part D Operations
D3 Self-Climbing Procedure
D3.1 Operating the hydraulic pump
5. Retracting the climbing device:
– Retract pistons of all hydraulic
cylinders.
– Claw (1.1) circumvents the climbing
bolts (9.1), hydraulic cylinder tips
backwards.
– Retract piston until claw on the piston
engages under the climbing bolts.
Are all claws engaged on the climbing
bolts?
Fig. 44: Retracting the climbing
device
6. Switching off the hydraulic pump:
– Turn the toggle on the motor
protection switch (3.2) to the left.
Hydraulic pump switches off.
Always switch off the hydraulic pump if
the climbing hydraulic is non-operational.