56
★
★
X
X
Indoor unit EEPROM parameter error
E4
——
★
X
X
Inverter module (IPM) malfunction
E5
P6
★
X
X
Outdoor temperature sensor(coil
sensor T3 or ambient temperature
sensor T4) malfunction or Outdoor
unit EEPROM parameter error
E6
E0,E4
★
★
X
Outdoor fan speed malfunction
E7
E8
★
X
Indoor fan speed malfunction
F5
——
★
X
Over-voltage or under-voltage
protection
P0
E5
★
★
★
X
Current overload protection
P2
P3
★
◎
X
X
Compressor drive malfunction
P4
——
★
X
Indoor units mode conflict
P5
——
★
flash at 2.5Hz,
light, X extinguished, ,
◎
flash at 0.5Hz
For Old Vertu/Luna Series
MS9AI-07HRDN1-M, MS9AI-09HRDN1-M(A),MS9AI-12HRDN1-M,MS9AI-18HRDN1-M;
MSV1I-09HRDN1-M, MSV1I-12HRDN1-M, MSV1I-18HRDN1-M;
De-frost
Timer
Auto
Operation
Failure
Display
Indoor unit EEPROM parameter error
E0
★
★
★
★
Communication malfunction between indoor and
outdoor units error
E1
★
★
Zero-crossing signal detection error
E2
★
★
Indoor fan speed malfunction
E3
X
X
★
Outdoor temperature sensor(coil sensor T3 or
ambient temperature sensor T4) malfunction or
Outdoor unit EEPROM parameter error sensor
E5
★
Indoor room temperature sensor(room sensor T1
or coil sensor T2) malfunction
E6
★
★
★
Outdoor fan speed malfunction
E7
X
X
★
Inverter module (IPM) malfunction
P0
X
★
Over-voltage or under-voltage protection
P1
X
X
★
High temperature protection of compressor top
(OLP)
P2
X
★
Low ambient temperature cut off in heating
P3
X
★
★
Compressor drive malfunction
P4
X
★
★
Indoor units mode conflict
P5
For All new models(New Wall mounted(Hi-Wall) series, New Duct/Cassette/Console/Floor
Ceiling):
1) Oasis:
Summary of Contents for 3PAMS18-HH-MZO2
Page 5: ...4 ...
Page 29: ...28 3PAMSH18 MZO2 5 ...
Page 30: ...29 6 2 Wiring diagram of 1 drive 3 outdoor M3OF 27HFN1 M ...
Page 31: ...30 3PAMSH27 MZO3 3PAMS27 HH MZO3 ...
Page 32: ...31 M3OH 27HFN1 M ...
Page 33: ...32 6 3 Wiring diagram of 1 drive 4 outdoor M4OF 36HFN1 M ...
Page 34: ...33 M4OH 36HFN1 M 3PAMSH36 MZO4 ...
Page 36: ...35 6 4 Wiring diagram of 1 drive 5 outdoor M5OF 48HFN1 M ...
Page 47: ...46 PCB board of M5OF 48HFN1 M M4OH 36HFN1 M ...
Page 51: ...50 PCB Board of 3PAMS48 HH MZO5 3PAMS36 HH MZO4 3PAMSH48 MZO5 ...
Page 53: ...52 IPM board of 3PAMS48 HH MZO5 3PAMS36 HH MZO4 3PAMSH48 MZO5 ...
Page 72: ...71 Operating els Standby Pic 2 IPM for 2 zone 3 zone ...
Page 91: ...90 Operating els Standby Pic 2 IPM board for 2 zone 3 zone ...
Page 93: ...92 PIC 4 Check point button press 1 time for check how many indoor units are connected ...
Page 99: ...98 IPM board for 4 zone ...
Page 103: ...102 Two ports of the inductance Inductance ...
Page 106: ...105 Vs Vcc Vsp FG ...
Page 110: ...109 ...
Page 113: ...112 ...
Page 116: ...115 ...
Page 120: ...119 Faulty outdoor PCB Trouble shooting ...
Page 129: ...128 ...
Page 136: ...135 Red Blue Red Yellow Brown Orange ...
Page 137: ...136 Brown White ...