58
★
9 times
X
EH
0b/Eb
Indoor PCB/Display board communication error
——
★
8 times
X
EE
Water-level alarm malfunction
——
★
7 times
X
EC
Refrigerant leakage detection
——
★
1 time
F0
Current overload protection
——
★
2 times
F1
Outdoor ambient temperature sensor (T4 ) malfunction
E4
★
3 times
F2
Condenser coil temperature sensor (T3) malfunction
E4
★
4 times
F3
Compressor discharge temperature sensor (T5) malfunction
E4
★
5 times
F4
Outdoor unit EEPROM parameter error
E0
★
6 times
F5
Outdoor fan speed malfunction
E8
★
7 times
F6
Indoor coil outlet pipe sensor(Located on outdoor unit low pressure
valve)
——
★
8 times
F7
Communication malfunction between Cassette optional lift panel
and the unit.
——
★
9 times
F8
Cassette optional lift panel malfunction
——
★
10 times
F9
Cassette optional lift panel not closed
——
★
11 times
FA
Communication error between indoor two chips(For A6 Duct)
——
★
1 time
★
P0
Inverter module (IPM) malfunction
P6
★
2 times
★
P1
Over-voltage or under-voltage protection
E5
★
3 times
★
P2
High temperature protection of compressor top(OLP)/ High
temperature protection of IPM board
——
★
4 times
★
P3
Low ambient temperature protection
LP
★
5 times
★
P4
Compressor drive malfunction
——
★
6 times
★
P5
(
——)
Indoor units mode conflict
——
★
7 times
★
P6
Low pressure protection
P2
★
flash ,
light, X extinguished
All Easy Pro type, Infini type
Operation lamp
Timer
lamp
Display LED STATUS
ODU
Error
★
1 time
X
EH
00/EH
0A
Indoor unit EEPROM parameter error
——
★
2 times
X
EL 01
Communication malfunction between indoor and outdoor units
E2
★
4 times
X
EH 03
Indoor fan speed malfunction
——
★
6 times
X
EH 60
Indoor room temperature sensor (T1 ) malfunction
——
★
6 times
X
EH 61
Evaporator coil temperature sensor (T2) malfunction
——
★
1 time
★
PC 08
Current overload protection
——
Summary of Contents for 3PAMS18-HH-MZO2
Page 5: ...4 ...
Page 29: ...28 3PAMSH18 MZO2 5 ...
Page 30: ...29 6 2 Wiring diagram of 1 drive 3 outdoor M3OF 27HFN1 M ...
Page 31: ...30 3PAMSH27 MZO3 3PAMS27 HH MZO3 ...
Page 32: ...31 M3OH 27HFN1 M ...
Page 33: ...32 6 3 Wiring diagram of 1 drive 4 outdoor M4OF 36HFN1 M ...
Page 34: ...33 M4OH 36HFN1 M 3PAMSH36 MZO4 ...
Page 36: ...35 6 4 Wiring diagram of 1 drive 5 outdoor M5OF 48HFN1 M ...
Page 47: ...46 PCB board of M5OF 48HFN1 M M4OH 36HFN1 M ...
Page 51: ...50 PCB Board of 3PAMS48 HH MZO5 3PAMS36 HH MZO4 3PAMSH48 MZO5 ...
Page 53: ...52 IPM board of 3PAMS48 HH MZO5 3PAMS36 HH MZO4 3PAMSH48 MZO5 ...
Page 72: ...71 Operating els Standby Pic 2 IPM for 2 zone 3 zone ...
Page 91: ...90 Operating els Standby Pic 2 IPM board for 2 zone 3 zone ...
Page 93: ...92 PIC 4 Check point button press 1 time for check how many indoor units are connected ...
Page 99: ...98 IPM board for 4 zone ...
Page 103: ...102 Two ports of the inductance Inductance ...
Page 106: ...105 Vs Vcc Vsp FG ...
Page 110: ...109 ...
Page 113: ...112 ...
Page 116: ...115 ...
Page 120: ...119 Faulty outdoor PCB Trouble shooting ...
Page 129: ...128 ...
Page 136: ...135 Red Blue Red Yellow Brown Orange ...
Page 137: ...136 Brown White ...