5. Remote Control 

 
A special compartment is provided for the remote control (fig.1 #4), so that it does not 
need to lie around while it is not being used. Open the compartment by pressing the left 
part (in the middle) of the compartment door until you hear a click. Release the door 
and it will swing open. The door has a basket for the remote control on the inside. 
If the remote control will not be used for a long time, remove its batteries before putting 
it into its compartment. 
 
The remote control display features the same information as the display on the device 
itself, except for the error notifications (see fig.4). The arrow in the upper right corner 
appears when a button on the remote control has been pressed to indicate the 
command has been sent ; it disappears after a few seconds. 
The remote control also features the same command buttons as the device itself, 
except for the temperature button, which is split in 2 here. 
 
The remote control operates on 2 AAA batteries (battery compartment at the rear). 
 

6. Accessories & Maintenance 

 
Air exhaust pipe (included) 
When using the device in cooling mode, make sure to connect the air exhaust pipe to the ventilation air outlet (fig.2 
#8) by means of the adapter. Lead the pipe to an open window or door so that the hot air does not return in the room.  
The pipe can be extended form 0.6 to 2 metres ; however, the device will work more efficiently when the pipe is 
shorter. Make sure the pipe is never distorted or blocked. If this should occur and hot air flows back into the device, 
the internal temperature sensor will cause the device to stop working. Do not extend the pipe longer than 2 meters or 
add extensions to it. 
 
Dehumidification – water tank / drainage pipe (not included) 
When using the unit to dehumidify the air, the device will produce condensed water. This can be collected in the 
water tank (fig.1 #5) or can flow away through a drainage pipe. 
When the water tank is being used and it is full, the buzzer will sound 20 times, the error code "E4" will be displayed 
on the LCD and the device will stop working. Empty the water tank immediately. Never remove the tank while the 
device is switched on! Clean the tank once in a while with hot water and a neutral detergent.  
To connect a drainage pipe, remove the rubber plug from the drainage connection (fig.2 #7). Do not throw away the 
plug since you will need it to use the 

EAC12

 without drainage pipe. Connect the drainage pipe to the output and lead 

it to where the water can safely flow away. Make sure the pipe is never distorted or squeezed. 
If the 

EAC12

 will not be used for a longer period of time, make sure all condensed water is removed. 

 
Air filter cleaning 
Loosen the screw at the top of the air filter cover (fig.2 #6) and remove the air filter. Wash the air filter by immersing it 
into warm (±40°C) water with a neutral detergent. Afterwards, rinse the filter thoroughly and let it dry in a shaded 
place. Put the filter back and fasten the cover with the screw at the top. 
 
General maintenance 
1.  The housing and visible parts should not be deformed, modified or tampered with. 
2.  Moving mechanic parts must not show any signs of wear and tear. 
3.  The power cable must not show any damage. Have a qualified technician maintain the device. 
4.  Disconnect the device from the mains prior to maintenance activities. 
5.  Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents. 
 

Summary of Contents for EAC12

Page 1: ...ke the device Avoid brute force when installing or operating the device Select a location where the device is protected against dust and direct sunlight Familiarise yourself with the functions of the...

Page 2: ...ing only in cooling mode by pressing the corresponding end of the button The selectable range is 15 31 C In AUTO mode the temperature is 23 C by default 6 TIMER to determine a time after which the dev...

Page 3: ...working Do not extend the pipe longer than 2 meters or add extensions to it Dehumidification water tank drainage pipe not included When using the unit to dehumidify the air the device will produce con...

Page 4: ...is reached This is perfectly normal E3 error code on LCD air filter Clean the air filter The device stops operating E4 error code on LCD water Empty the water tank see 6 Accessories Maintenance Room t...

Page 5: ...de buurt van kinderen en onbevoegden Schud het toestel niet dooreen Vermijd brute kracht tijdens de installatie en de bediening van dit toestel Installeer het toestel weg van stof en direct zonlicht L...

Page 6: ...zie hieronder 5 TEMP om de temperatuurinstelling te regelen enkel in koelmode door de boven of onderzijde van de knop in te drukken Het selecteerbare bereik is 15 31 C In AUTO mode is de temperatuur...

Page 7: ...2 meter en voeg er geen verlengstukken aan toe Ontvochtigen waterreservoir afvoerdarm niet meegeleverd Wanneer u het toestel gebruikt als luchtontvochtiger zal het condenswater produceren Dit kan word...

Page 8: ...is ten einde temperatuur is bereikt Dit is normaal E3 foutcode op LCD luchtfilter Reinig de luchtfilter Het toestel stopt met werken E4 foutcode op LCD water Maak het reservoir leeg zie 6 Toebehoren o...

Page 9: ...l appareil et traitez l appareil avec circonspection pendant l installation et l op ration Choisissez un endroit o l appareil est prot g contre la poussi re et la lumi re solaire directe Familiarisez...

Page 10: ...de refroidissement en pressant le bout correspondant du bouton La port e est de 15 31 C En mode AUTO la temp rature est 23 C par d faut 6 TIMER pour d terminer une p riode apr s laquelle l appareil s...

Page 11: ...us de 2 m tres et n y ajoutez pas de rallonges D shumidification r servoir d eau tuyau de vidange pas inclus Quand l appareil sert d shumidifier l air l appareil produira de l eau de condensation qui...

Page 12: ...rmal code d erreur E3 sur LCD filtre d air Nettoyez le filtre d air L appareil arr te de fonctionner code d erreur E4 sur LCD eau Videz le r servoir voir 6 Accessoires entretien temp rature ambiante e...

Page 13: ...l enchufe para desconectar el cable de red nunca del propio cable Mantenga el EAC12 lejos del alcance de personas no autorizadas y ni os No agite el aparato Evite usar excesiva fuerza durante la insta...

Page 14: ...la LCD v ase abajo 5 TEMP para ajustar la temperatura s lo en modo de refrigeraci n al pulsar o El rango seleccionable es de15 a 31 C En el modo AUTO la temperatura est ndar es de 23 C 6 TIMER tempori...

Page 15: ...s Deshumidificar dep sito de agua tubo de descarga no incl Al utilizar el aparato como deshumidificador producir agua condensada Esta agua se re ne en el dep sito de agua fig 1 5 o se puede dejar flui...

Page 16: ...o es completamente normal El mensaje de error E3 aparece en la pantalla LCD filtro de aire Limpie el filtro de aire El aparato deja de funcionar El mensaje de error E4 aparece en la pantalla LCD agua...

Page 17: ...Netz Fassen Sie dazu den Netzstecker an der Grifffl che an und ziehen Sie nie an der Netzleitung Halten Sie Kinder und Unbefugte vom Ger t fern Vermeiden Sie Ersch tterungen Vermeiden Sie rohe Gewalt...

Page 18: ...he unten 3 SPEED um die Geschwindigkeit des Ventilators zu w hlen LOW MID oder HIGH Die Geschwindigkeit des Ventilators wird auch auf dem LCD gezeigt Abb 4 6 4 LCD Schirm siehe unten 5 TEMP um die Tem...

Page 19: ...4 Das Pfeilchen in der rechten oberen Ecke zeigt an dass eine Taste auf der Fernbedienung gedr ckt und das Befehl gesendet wurde es verschwindet nach einigen Sekunden Die Fernbedienung hat auch diesel...

Page 20: ...ilden Reinigungsmittel Sp len Sie nachher den Filter ab und lassen Sie ihn im Schatten trocknen Bringen Sie den Filter wieder an und Schrauben Sie den Deckel wieder auf Allgemeine Wartung 1 Das Ger t...

Page 21: ...EAC12 21 PEREL 8 Schaltplan Alle nderungen vorbehalten...

Reviews: