User Manual
4.2.2 Physical contacts (inputs and outputs)
To configure the Settings of the controller inputs and outputs:
1. Click consistently in the Web-interface menu:
“Configuration”
→
“Edit”
→
“Physical
contacts”
.
The page with working area will be opened:
The page lists all the controller inputs and outputs.
By default, for inputs and outputs which are used for OD (lock) operation
corresponding functions are set (for inputs – PASS / RC, for outputs – OD operation /
RC-panel indication) and there are set number and direction of OD, to which current
contact is connected.
For inputs and outputs which are not used for OD operation, by default, value
“Not
specified”
is set. These outputs and inputs are available for setting (and changing in
future) its functions.
Name in Web-
interface
Function
Wire color
Input 1
Always – Door sensor,
Door
(
Pass
)
white
Input 2
Always – RC-button,
DU
green
Output 1
Always – Lock operation,
Lock
orange
Input 3 / Output 2
1) Input
Fire
Alarm
,
2) Output
Alarm
(siren),
3) Input - output
SYNC
(synchronization of 2
controllers)
brown
Notes:
Input 3
or
Output 2
of
CL-05.2
controller are led in one leading-out wire – brown
wire.
“SYNC” function (synchronizing input-output for common operation of 2
CL-05.2
controllers) for input 3 / output 2 can be set only via net software of PERCo
systems (see Operating Manual, Section 5.4.3).
It is possible to restore to factory default settings by resetting configuration
template (see Clause 4.1).
2. Click in the working area of the page on the line with the name of the input (output).
The window with the physical contact will be opened:
30
Summary of Contents for CL-05.2
Page 1: ...Lock Controller CL 05 2 OPERATION MANUAL ...
Page 2: ...Lock Controller CL 05 2 Operation Manual ...
Page 15: ...Operation Manual Figure 3 Controller connection scheme 14 ...
Page 24: ...CL 05 2 Lock Controller Figure 5 Controller connection scheme through PoE splitter 23 ...
Page 40: ......
Page 42: ...www perco com ...