CL-05.2 Lock Controller
11 OPERATION
Observe safety instructions given in Section 7.2 during controller operation.
Do not!
Use abrasive or chemically active materials for cleaning external surfaces of
controller housing.
Jerk and hit controller housing, lock, door sensor, RC-button and connecting
cables in order to prevent their mechanical damage or deformation.
After configuration initiation controller can operate in the following modes:
Without connection to ACS (access control system) server
In case connection to
Ethernet
network and to the PC is unavailable, controller will start
executing the following functions:
Accepts presented cards identifiers from the built-in reader and, in accordance with
their existence in the list, stored in controller memory, grants or bans the access.
Controls the connected OD.
Arms and disarms protective zones, controls OD in
“Arming”
ACM; activates
additional output in
“Alarm”
mode.
Fixes events in the controller memory event log.
Supports passage time control and commissioning function.
Global zoning control function becomes available when controller is connected to the
network and when connection with other system controllers is provided.
Connecting to the PC with
“Local Software”
installed:
Events from log event are automatically relocated into programme database each
time the programme is initiated. The data can be also relocated by clicking on the
corresponding button in the programme.
Data on identifier owner (full name) are stored in programme database.
Verification is available in case
“Local Software with verification”
is installed.
Connected to ACS (access control system) server
Apart from the functions, supported during standalone operation, the following functions
also become available:
Data from the log event get automatically relocated into security system server
database.
Verification function is available depending on network Software modules installed.
11.1 ACM when operating as a part of ACS
ACM change is performed by the simultaneous order from the Software to both passage
directions.
Controller as a part of ACS provides the following ACM through OD (ACM indication is
given in Table 4):
“Open”
ACM
–
free passage mode.
OD gets unlocked until ACM change.
RC-button
(
“Exit”
) pressing is ignored.
“Control”
ACM – main operation mode as an ACS element.
OD is blocked.
17
Summary of Contents for CL-05.2
Page 1: ...Lock Controller CL 05 2 OPERATION MANUAL ...
Page 2: ...Lock Controller CL 05 2 Operation Manual ...
Page 15: ...Operation Manual Figure 3 Controller connection scheme 14 ...
Page 24: ...CL 05 2 Lock Controller Figure 5 Controller connection scheme through PoE splitter 23 ...
Page 40: ......
Page 42: ...www perco com ...