1. Controller connection through PoE-splitter
Attention!
Instruction provided refers to the splitters included in additional equipment
delivery set.
Total power consumption of the controller and of all the devices powered by it
should not exceed 12 W. It is also recommended to leave min 10% reserve
power.
Splitter description
PoE-splitter
(hereinafter –
splitter
) is designed for energizing equipment, connected via
Ethernet
network. Splitter operates with any network commutators (hereinafter –
Switch)
,
supporting technology of electric power transmission via
PoE
twisted pair wire and
compatible with
IEEE 802.3af
standard.
Splitter is designed as a block of electronics in a plastic housing featuring the following
outputs:
Con 1
– output for
Ethernet
cable from
Switch
connection.
Con 2
– output for
Ethernet
controller cable connection;
Con 3
– power output for controller power cable connection.
Note:
For some models of splitters output voltage is chosen with the switcher. Operating
with
PERCo
equipment it is necessary to turn the switcher into
“12V”
mode.
Connection sequence
Follow this sequence during controller connection through splitter:
1. Choose splitter installation place. Do not install splitter at more than 2 m distance
from the controller.
2. Connect
Ethernet
cable from controller to
Con2
output of the splitter (Table 3).
3. Connect controller power-supply circuits to
Con3
output of the splitter. Connection
scheme is given in Fig. 5 (other connections are to be made according to Fig. 3,
Fig. 4, attachment plug for connection to the output is included into splitter delivery
set).
Attention!
It is
OBLIGATORY
to install a spark protection diode
VD1
(Fig. 3, Fig. 4) of 1N5819
type during lock connection.
DO NOT
use suppressors instead of spark protection
diodes
.
It is recommended to use electromechanical locks only.
4. Connect
Ethernet
cable from
Switch
to
Con1
output of the splitter.
5. After verification between
Switch
and splitter, controller will be energized.
Disconnect
Ethernet
(coming from
Switch
) cable from
Con1
output of the splitter to de-
energize controller.
22
Summary of Contents for CL-05.2
Page 1: ...Lock Controller CL 05 2 OPERATION MANUAL ...
Page 2: ...Lock Controller CL 05 2 Operation Manual ...
Page 15: ...Operation Manual Figure 3 Controller connection scheme 14 ...
Page 24: ...CL 05 2 Lock Controller Figure 5 Controller connection scheme through PoE splitter 23 ...
Page 40: ......
Page 42: ...www perco com ...