Operation Manual
In this case it can be said that IP-packets are not fragmented to the size smaller than
576 bytes and the chosen connection should function correctly.
If it is impossible to get the positive answer, this means that on the IP-packet route
there is a network commutating equipment, fragmenting IP-packets up to the size
smaller than 576 bytes. Check the settings of this equipment and, if possible, increase
MTU
size. Usually this parameter is marked as
MaxMTU
or
IPMTU
.
5.
If several variants of commutation are possible
, use this command.
ping x.x.x.x -l 576 -t
Commutating in different ways, look at the response time, choosing the connection,
giving the quickest response time.
6.
Controller malfunctions.
Faulty operation of the elements, providing connection via
Ethernet (IEEE 802.3)
interface.
If controller does not detect connection to
Ethernet
, connect it to the cable, from which
another controller operates. If controller does not detect connection to
Ethernet
or
connection with it cannot be restored, i.e. this controller is to be sent back to the
manufacturer for diagnostics.
12 TRANSPORTATION AND STORAGE
Controller in the original package should be transported in closed freight containers or
other closed type cargo transport units.
The storage of the controller is allowed indoors at ambient temperature from -20°C to
+40°C and relative air humidity up to 98% at +25°C.
20
Summary of Contents for CL-05.2
Page 1: ...Lock Controller CL 05 2 OPERATION MANUAL ...
Page 2: ...Lock Controller CL 05 2 Operation Manual ...
Page 15: ...Operation Manual Figure 3 Controller connection scheme 14 ...
Page 24: ...CL 05 2 Lock Controller Figure 5 Controller connection scheme through PoE splitter 23 ...
Page 40: ......
Page 42: ...www perco com ...