Edit OITControl menu > Repeat read operation
Figure 9.8
OITControl
Repeat read procedure
The read operation of the connected OIT system can be repeated here. This
initiates a complete read operation, including communication to the PLC host
computer.
9.2.3
OITControl menu Process > Camera image
Figure 9.9
Camera image dialog box opended
With the help of the live image function in OITControl, the administrator or primary
user has the option of checking the alignment of the OIT system, the display
window and its sharpness, image brightness and contrast, and, if necessary,
adapting them to the needs of their equipment. There is also the option in the
drop-down menu to display fault patterns and an evaluation with or without the
hole recognition markings. A partial image can be pre-defined in the menu
Only
display partial image
under
Configuration > Configure OITControl > Image
display tab
. You also have the option of saving the images in pgm format so that
you can send these images to P+F in the event of a support query, for example.