OIT***-F113-B12-CB*
OITControl
Correct read errors: Manual entry
A instance may occur when the OIT system cannot read the data from a read-only
tag. In this case, the buttons
Manual entry of ID/UID number(s)
and
Repeat
read operation
will flash in the tool bar. Proceed as follows in order to correct the
read error by manually entering the data:
1. Click
or
select
Process > Manual entry
.
The dialog window
Manual data entry
will open:
Figure 8.8
OITControl
Manual data input
2. Enter the ID number of the read-only tag into the box
Entry box for ID
number
. Enter the check digit of the read-only code into the second box.
Optionally, the UID number may also be entered. For example: a defective
read-only tag is replaced by a new read-only tag that merges with the UID
number to create a unique identification code.
3. Click
OK
.
The entered data is checked and subsequently sent to the OIT system.
The manually entered data is displayed in the
Manual UID Number
and
Manual ID number
on the tab
OIT data set readout
. "XXXXXX" is displayed
for
ID number
.