Trigger Telegram (via Port 10100 for Software Triggering)
Status Table: Bytes 7
–
10
Byte 0
Byte 1
Byte 2
Byte 3
Start character
Command: read code
End character 1
End character 2
#(23 hex)
R (52 hex)
CR (0D hex)
LF (0A hex)
Byte
Group
description
Subgroup description
7
8
9
10
bin
bin
bin
hex
Bit 0
OITControl client connected
Bit 1
Parameterization lock active
Bit 0
Function
could not be
started or is
not running
HTTP server not available
Bit 1
FTP server not available
Bit 2
NTP server not available
Bit 3
Logging program not running
Bit 4
Data Matrix decoder not active
Bit 5
Decoder not active
Bit 0
OIT
warnings
(The read-
only tag
could still be
read)
Camera image too bright
Bit 1
Camera image too dark
Bit 2
Too many structures in image
Bit 3
The distance between the read-only tag and OIT system is too
great
Bit 4
The distance between the read-only tag and OIT system is too
small
Bit 5
Not enough contrast
Bit 6
The read-only tag is outside of the detection/capture range
0x01
OIT status
(The read-
only tag
could no
longer be
read)
No punched holes found
0x02
Few punched holes found, first loop
0x03
Few punched holes found, second loop
0x04
No check marks found in range, check 1
0x05
Decryption not possible, check 1
0x06
No check marks found in range, check 2
0x07
Poor contrast
0x08
No check marks found in range, check 3
0x0A
No check marks found in range, check 4
0x0B
Decryption not possible, check 2
0x0F
Checksum error
0x2A
Timeout
0x31
Poor read-only tag (too many possible hole structures)
0x32
Timeout while determining the corner points
0x33
Timeout while decoding
0x99
Maximum repeat read reached
Double code-reading
0x9A
Disconnect in process
0xFE