OIT***-F113-B12-CB*
OITControl
Transferring the current settings from the OIT system
It is possible to transfer the current parameter settings from the OIT system to
OITControl. To do so, proceed as follows:
1. Choose
Configuration > OIT system configuration
.
2. If the
Invalid parameter data...
window opens, close it by clicking
OK
.
The
OIT system parameterization
dialog box opens.
3. Click
Require parameter data
in the
OIT system
area.
The current parameter settings are now transferred from the OIT system
to OITControl.
Configuring network settings
In order to adapt the network settings to the requirements of your network,
proceed as follows:
1. Select
Configuration > Configure OIT System
.
2. If the window
Invalid parameters...
pops up, close it by clicking on
OK
.
A dialog window
Parameterization of the OIT system
will open:
Figure 8.13
Network
tab
3. In the area
Ethernet
change the settings for
IP address
,
Subnet Mask
, and
Gateway
in the appropriate fields according to the requirements of your
network.
4. If a clock server is going to be used, enter the IP address of the clock server
into the area
NTP1-Server
. As a backup, another clock server can be entered
into
NTP2-Server
.
5. Take all remaining values as the default values.
6. In order to send the settings to the OIT system, click the button
Write
parameters
in the
OIT system
area.
7. In order to close the
Parameterization of the OIT system
dialog window,
click on
END
.
Note!
Acceptance only after restart
In order to accept the changes in the system, the OIT system must be restarted.