OIT***-F113-B12-CB*
OITControl
19
9165
201
3-
06
39
■
Right display area
: with the OITControl default configuration, the right
side display area provides detailed information on the connected OIT
system. This information is arranged into tabs. The following tabs are
available in the default configuration:
•
OITControl messages
: All OITControl actions are logged here
and saved in a file on the computer hard drive.
•
OIT data set
: In the default configuration, the numbers of the
evaluated code carrier and the manually entered numbers are
displayed here. If no OIT system is connected, the values in braces
provide information on start position and the number of characters
from the data set to be read.
ID number: {262|6}
means that the
ID number in the data telegram begins at Position 262 and is 6
characters long. The most recently generated image is also
displayed.
•
OIT debug display
: The OIT system evaluates the captured
images with regard to several factors. If the captured image is
recognizable and a read error occurs due to a deterioration of the
ambient conditions, then the tab
OIT debug display
OIT Debug
display will provide further information as to possible causes.
Fault messages
-
No holes or not enough holes found [1, 2, 3, 4]
-
Code sheet cannot be decoded [5]
-
Insufficient contrast on code sheet [7]
-
Corner holes on code sheet not found [6, 8, 10, 11]
-
Invalid check sum [15]
-
Sheet quality insufficient [49]
-
Timeouts [42*, 50, 51]
-
Intern software error [negative value]
The status bar is displayed at the bottom of the screen. The left side of the status
bar shows the last action executed along with date and time. The connected OIT
system appears on the right side of the status bar.
Figure 8.3
OITControl status bar