35
SunTouch
®
Control System Installation and User’s Guide
Pump Menu (12/14)
(Continued)
IntelliFlo
®
VSF+SVRS Pump
From the IntelliFlo
®
VSF+SVRS Pump menu you can assign circuits to control the pump flow rate (GPM/
RMP), priming, also filter, backwashing, vacuum functions and view the current pump status. For more
information about the IntelliFlo VS Pump, refer to the IntelliFlo VF Pump Installation and User’s Guide (P/N
350075).
To assign up eight (8) pump speeds and circuits for the IntelliFlo VS pump:
Menu button:
Select the
Pumps
12/14
menu.
Right button:
Press the button to view the type of pump to select.
Up/Down buttons:
Select
IntelliFlo VF
them press
Right button
again to select.
Press
Up/Down buttons
to view the
Pump Parameters
menus:
CIRC. SETUP
, and
STATUS.
Press
Right button
to choose one of the parameters.
CIRCUIT SETUP:
Press
Right button
to assign a circuit to the pump. Press
Up/
Down buttons
to view the circuits for the first of eight (8) pump circuits:
[NONE,
SPA, POOL, AUX 1, AUX 2, AUX 3, FEATURE 1-4, SOLAR, HEATER, POOL
HEAT, SPA HEAT, FREEZE, POOL/SPA, and SOLAR/HT (solar/heater)].
GPM/RPM Mode:
Press the
Right button
to set the GPM and RPM pump speed.
Press
Up/Down button
to toggle between RPM and GPM/PSI.
The Assign Flows screen displays. Press
Up/Down buttons
to set the pump flow
rate from 15 - 130 GPM. The default flow rate is 30 GPM. The preset speed for each
button is:
Speed 1 button 1100 RPM (30 GPM), Speed 2 button 1500 RPM, Speed
3 button 2350 RPM, and Speed 4 button 3110 RPM.
Press the
Right button
again to set the PSI setting. Press
Up/Down buttons
to set
pump pressure setting from 1 to 30 PSI.
Press
Right button
to select the circuit.
Note: Selecting “Pool/Spa” or
“Solar/HT” combines several circuits into the same pump speed for pool and spa or
for solar and heater combination systems. Normally this would require programming
two separate pump speeds for each function. Using one of these selections, free-up
one of the four pump speed for other uses.
Press
Right button
to continue to assign pump
FILT. CIRC.
and
CIRCUITS
. You
can assign up to eight (8) pump speeds and circuits.
When finished assigning pump flow rate and circuits, press the
Right button
until
FLOWS
is displayed, then press the
Up/Down buttons
and select
FILTER
.
Press
Right button
to select
Assign Flows
. Press the
Up/Down buttons
to set the
flow rate from 15-150 GPM.
Press
Right button
to select
Assign PSI
. Press the
Up/Down buttons
to set the
pressure rate from 1-30 PSI.
Left button:
Press the Left button to return to the main status screen.
Assign Flows
1 - GPM: 80
Main Menu 12/14
Pumps
Circuit Setup
1 - [ POOL ]
Pump Type
[INTELLIFLO VF ]
Pumps Parameters
Menu: CIRC. SETUP
GPM/RPM Mode
GPM (RPM)
Assign Circuit
1 - [SPA ]
Assign Speeds
1 - RPM: 7710
Assign Flows
1 - GPM: PSI
Assign PSI
1 - PSI: DSBL