Control System Installation and User’s Guide
Advanced Menu (8/14): Reset Factory
SunTouch
®
Control System configuration data is stored and retained in “Flash” memory in an EEPROM
located on the SunTouch Control System motherboard. The SunTouch Control System user system
configuration data can be erased to restore the factory defaults settings. If the optional QuickTouch
®
QT4
Wireless Remote is installed it will need to be reconfigured.
Reset to factory default settings
Menu button:
Select the
Advanced 8/14
menu.
Right button:
Press this button until RESET FACTORY ERASE ALL? setting is
displayed.
Up/Down button:
Select
Yes
to continue. Select
No
to exit the setting.
Right button:
Press this button to continue. “Erase Memory” is displayed.
Up/Down button:
Select
Yes
to continue. Select
No
to exit the setting.
Right button:
Select
Yes
to erase system data and restore the factory default
settings. The display will return to the main screen.
CAUTION: This procedure will
erase all system settings.
Select
No
to exit the setting.
Diagnostics Menu (9/14): Firmware Rev
Displays the current firmware revision for the SunTouch Control System.
Menu button:
Select the
Diagnostics 9/14
menu.
Right button:
View the SunTouch Control System firmware revision.
Left button:
Press the Left button to return to the main status screen.
Diagnostics Menu: Solar Temp
Displays the current solar temperature.
Menu button:
Select the
Diagnostics 9/14
menu.
Right button:
Press the button until
SOLAR TEMP
displays. Use this feature for
testing purposes and to verify the sensor temperature is connected and operating
correctly.
Left button:
Press the Left button to return to the main status screen.
Diagnostics Menu: Self Test
To run a system self test:
Menu button:
Select the
Diagnostics 9/14
menu.
Right button:
Press the button until Enter
SELF TEST
displays.
Up/Down button:
Select
Yes
to continue. Select
No
to exit the Diagnostics menu.
Right button:
Start the SunTouch Control System self test. The test includes testing
the control panel, air and water sensors and valves. Follow the on-screen instructions.
After the test has been completed, the status screen will displays the results. A
successful test will display -
Status: Passed - Code: None
. See page 66 for error
codes.
Left button:
Press the Left button twice to return to the main status screen.
Diagnostics Menu: IntelliChem
®
Controller
To view the current IntelliChem
®
Controller pH and OPR status an RS-485 cable must be connected to the
COM port on the SunTouch Control System (see page 56) and IntelliChem Controller circuit board.
Menu button:
Select the
Diagnostics 9/14
menu.
Right button:
Press the button until
IntelliChem
control system
is displayed.
Left button:
Press the Left button twice to return to the main status screen.
Firmware Rev
Rev: 2.0
Main Menu 9/14
Diagnostics
Status: Passed
Code: None
Solar Temp
Temp: 77 F
Enter
Self Test? Yes
Main Menu 9/14
Diagnostics
Main Menu 9/14
Diagnostics
Reset Factory
Erase All? Yes
Main Menu 8/14
Advanced
Erase Memory?
[YES ]
SunTouch
7:30 AM
IntelliChem
pH: 7.50 ORP:735