background image

-Hour   : 16 h

 Minute : 03 min.

  - Once the SPEEDEO is linked to a SOLEO, this menu 

Setting the time

 disappears. The SOLEO 

will manage the time settings. 

  - Once the SPEEDEO is linked to a SOLEO, this menu 

Filtration Length

 disappears. The 

SOLEO will manage the filtration length. 

-Filtration : ON    

 Star t      : 05:00

 Stop       : AUTO

 mode       : TURBO

Menu: Filtration Length / Auto/On/Off/Timer/Shock Mode

Filtration speed menu

Time set menu

-Mode: AUTO

 Events

-Mode  : MANUAL

 Speed : S2

 S2 timer   : YES

 Star t      : 11:00

 End        : 16:00

 S3 timer   : YES

 Star t      : 17:00

 End        : 18:00

 Cover open : NO

 Heating    : NO

 S3 inlet 1 : YES

Event creation:

S2 timer

 = If 

YES 

the pump is running at S2 from the 

Start time

 to 

End

S3 timer

 = If 

YES 

the pump is running at S3 from the 

Start time

 to 

End

Cover open

 = Opening the cover (if connected) changes the speed from 

S1 to S2.

Heating 

= Starting the heating pump (see p13) activates S2.

Inlet 1 S3 

= Closing a contact at Inlet 1 starts S3 (e.g. connecting a switch 

for activating a waterfall, an animation, swimming against the current...).

Select current mode:

AUTO

 = Automatically calculates the filtration length according to the water 

temperature.

ON

 = Filtration runs 24/7.

OFF

 = Filtration stops 

(note - anti freeze mode becomes inactive)

.

TIMER

 = Filtration runs during the selected time period (see below)

CHOC

 = Activates 24-hour filtration. This function can be useful after the pool 

has been used by many visitors and when the pool temperature is high. At the 

end of the mode 

CHOC

, SPEEDEO returns to normal 

AUTO

This menu gives you control of the filtration start and end time, to control the level of noise linked to your pool (filtration noise), 

for the sake of the neighbourhood. By default, leave 

End

 on 

AUTO

.

In 

AUTO

, SPEEDEO calculates the filtration end time.

MANUAL

 displays the field 

Speed

 which enables 

manual selection of the rotation speed for the pumps 

with variable speeds.

In 

AUTO,

 these events which adjust the different rotation 

speeds for the pumps with variable speeds. The field for 

Events 

will appear.

Home menu > Filtration Length menu:

Home menu > Filtration Length menu:

Makes it possible to set the time of the device. If the power supply is interrupted for more 

than 30 min., reinstalling the time is necessary.

17

Summary of Contents for SPEEDEO SB-PF-SPO-003C

Page 1: ...ernal connection which permits them to be externally controlled The list of compatible pumps is constantly changing in accordance with releases of new models 01 03 Water 24 3 C Filtration V2 S1 OFF S2...

Page 2: ...ty excluding probes and consumables 2 years 2019 Pentair International LLC All rights reserved The document is subject to change without notice Trademarks and disclaimers Speedeo Soleo and Pentair are...

Page 3: ...peeds Invertek convertor connection MENUS Main menu Radio menu Install Heating pump Information menu Filtration Length Filtration Speed Set Time CONNECTIONS Inlets Outlets Inlet connection for the end...

Page 4: ...her conductors except if the conductors are also protected by a differential interrupter Refer to valid local codes for more details WARNING This product must be installed by an authorised or certifie...

Page 5: ...em causing incorrect water chemistry which could harm people or equipment WARNING Consult the device display daily to ensure there are no alarm messages DANGER Water temperatures greater than 37 7 C 1...

Page 6: ...operation is linked to a speed The rotation speeds at different speeds are directly pre set on the control unit drive of the pump SPEEDEO will therefore select the most appropriate power according to...

Page 7: ...mber of visitors or by default or 30 value can be adjusted Possibility to change into SHOCK mode forcing of the filtration and electrolyser for 24 hours Possibility to change the speed according to th...

Page 8: ...lator of acidic vapours and humidity circulating via the screw hole Fuse holder 1 A 250 VAC Status light for updates Elastomer cover Insulator of acidic vapours and humidity SPEEDEO automatically cont...

Page 9: ...oom which cannot be accessed by children Set the device at a height lower than 2 m using three screws 4 to 5 mm diameter in appropriate plugs for the type of support and fix the device vertically on a...

Page 10: ...device is permanently connected The power supply to the device is cut by its interrupter which must be close and must remain accessible at all times The device needs to be connected to the earth and i...

Page 11: ...f installation types Controlling a solenoid valve with SPEEDEO makes it possible to benefit from full power for activities using V3 Opening the solenoid valve will stop the flows in the main circuit a...

Page 12: ...select T Air to indicate that a temperature sensor is connected to the corresponding inlet INSTALLATION OF THE AIR TEMPERATURE PROBE OPTION If the air temperature probe is connected it automatically...

Page 13: ...he diagram 2 Start the secured Install menu on the main menu press Esc and Valid at the same time for 3 secs A star appears in the top right corner of the home screen 3 On the Filtration Speed Type su...

Page 14: ...he Filtration Speed Type sub menu select 3 speeds and hold down Valid HAYWARD VSTD Connections and functions ZODIAC FloPro VS Connections and functions 1 Connect the cables in accordance with the diag...

Page 15: ...ain menu press Esc and Valid at the same time for 3 secs A star appears in the top right corner of the home screen 3 On the Filtration Speed Type sub menu select 4 speeds and hold down Valid This asse...

Page 16: ...channel and at a distance maximum 30 m will automatically be paired If several different Combi installations are close to each other it is possible to shift the radio channel of one of the installati...

Page 17: ...n Esc and Valid for 3 secs Astar appears in the top right corner of the home screen Access to restricted access mode Install Menu organisation Heating menu Information menu Heating pump Calibration An...

Page 18: ...filtration according to the water temperature Menu Filtration Length daily Algorithm This control increases or decreases the filtration time TURBO increases the filtration time modifiable factory sett...

Page 19: ...t Select current mode AUTO Automatically calculates the filtration length according to the water temperature ON Filtration runs 24 7 OFF Filtration stops note anti freeze mode becomes inactive TIMER F...

Page 20: ...ting despite the setting of an hour from the start and or end of filtration if the cover does not cover the pool all day filtration will run all day 5 On the Filtration Speed Events Cover Open sub men...

Page 21: ...orresponding outlet This contact is closed active outlet while the filtration is running whatever the rotation speed The connected control is guaranteed to function while the filtration pump is runnin...

Page 22: ...enu Setpoint will then appear Select Setpoints to change the target value A menu Priority will then appear Select Priority to activate or not The priority will activate the filtration and heating pump...

Page 23: ...nnect the cables in accordance with the diagram 2 Start the secured Install menu from the main menu simultaneously hold down Esc and Valid for 3 secs A star appears in the top right corner of the home...

Page 24: ...th chosen terminal select OTHER to indicate that a motorised valve is connected to the corresponding outlet 1 Connect the cables in accordance with the diagram 2 Start the secured Install menu from th...

Page 25: ...If filter washing is started manually the filtration time meter which activates automatic backwash is reset to zero Outlet connection for a pneumatic valve FILTER WASHING Valid to start washing Washin...

Page 26: ...he filtration pump for the length of time entered into the Washing XX secs SPEEDEO starts the filtration pump for the length of time entered into the Rinsing field XX secs SPEEDEO supports you in wash...

Page 27: ...ed filtration YES NO S2 timer YES NO S3 timer YES NO Cover open YES NO Heating YES NO S3 inlet 1 YES NO Filter washing Manual backwash Valid to start washing Filtration 100 h Washing 70 secs Rinsing 3...

Page 28: ...emp water 25 1 C Temp air 27 8 C Antifreeze 3 C Information Firmware version Languages LANGUAGE FRANCAIS ENGLISH Update To update firmware insert the USB stick and hold down the Up key Radio Radio cha...

Page 29: ...r lights up 5 2 In the main menu at the bottom under Information read the version no X X and check that it has changed 5 3 Replace the orange safety cover 5 4 Replace the soft cover 2 1 Remove the sof...

Page 30: ...lorine Despite the excess dose of chlorine the water is just disinfected but by contrast it is saturated pH 8 5 Cl 0 2 mg ORP 500 mV The pH is so high that it cancels out the disinfectant effect of th...

Page 31: ......

Page 32: ...1004 LAUSANNE Switzerland Copyright Limited Licence except as specifically permitted herein no portion of the content of this document may be reproduced in any form or by any means without the prior...

Reviews: